TEST PROCEDURES
(CONT'D)
PROCEDURE
LETTER
A
(Cont'd)
B
C
T
I-
!
I
-!-
I
I
/
I
I
I
I
I
I
I
c
I
/
/
I
1
I
I
/
i
COMPONENT
TEST
Calculation
of output
power;
Microwave
output
power
. . .P (W) = 70 x m
("C)
aT
=
(ATL + ATR)
2
: average temperature
rise
ATL = (TL2 - TL, )
ATR = (TR2 - TR1 )
TL2
:
water temperature
after heating in left beaker
J-L1
:
water temperature
before heating in left beaker
TR2
:
water temperature
after heating in right beaker
TRI
:
water temperature
before heating in right beaker
Measuring condition;
As the microwave
output
is affected
by several conditions,
the measurement
should be made
carefully
with following
attentions.
1. Initial
temperature
of salt water should be 2OAl'C.
(The salt water should be contained
bon (1)
percent of salt.) Well and quickly
stir the water and the temperature
measurement
should be
done immediately
after heating.
2. The graduation
of thermometer
should be scaled by O.l'C at minimum
and an accurate mercury
thermometer
is recommended.
3. Water container
should be one (1) litre beaker made of Pyrex glass and its diameter
approximately
12 cm.
4. Room temperature
should be around 2O'C.
5. Power supply voltage should be 240 volts.
POWER
TRANSFORMER
TEST
DISCHARGE
THE
HIGH
VOLTAGE
CAPACITOR
BEFORE
TOUCHING
ANY
OVEN
COMPONENTS
OR WIRING.
Disconnect
primary
input
terminals
and measure the resistance with an ohmmeter.
Check for the
continuity
of coils with an ohmmeter.
On the RX1 scale, the resistance of the primary
coil should be
approximately
1.5 ohms and the resistance of high voltage coil should be approximately
80 ohms,
and the resistance of filament
coil should be less than 1 ohm.
(HIGH
VOLTAGES
ARE
PRESENT
TO
HIGH
VOLTAGE
TERMINAL,
SO
THAT
DO NOT INTEND
TO MEASURE
THE FILAMENT
AND
HIGH
VOLTAGE,)
RECTIFIER
TEST
DISCHARGE
THE
HIGH
VOLTAGE
CAPACITOR
BEFORE
TOUCHING
ANY
OVEN
COMPONENTS
OR WIRING.
Isolate the rectifier
from the circuit.
Using the highest ohm scale of the meter, read the resistance
,
across the terminals
and observe,
reverse the leads to the rectifier
terminals
and observe meter
/
reading. If a short is indicated in both directions,
or if an infinite
resistance is read in both directions,
the rectifier
is probably
defective and should be replaced.
32