TEST
PROCEDURES
(CONT'D)
' PROCEDURE
LETTER
r G
1
(CONT'D)
!
H
I-
/
I
T
-~
COMPONENT
TEST
POWER TRANSFORMER
BLDWN
FUSE
If the fuse in the upper latch switch,
monitor
switch and lower
latch switch
circuit
is blown when
the door is opened,
check the upper and lower
latch switches
and monitor
switch before replacing
the blown fuse. (Refer
to above Test Procedure
E, F and G).
In case the fuse is blown by an improper
switch operation,
replace the defective
switch and the fuse
at the same time.
Replace just the fuse if the switches operate
normally.
CAUTION:
REPLACE
BLOWN
FUSE
10 AMPERE
FUSE,
PART
NO. QFS-CQOOIYBEO
+
MAGNETRON
TEMP.
FUSE
TEST
A continuity
check across the temp. fuse terminals
should indicate
a closed circuit
uniess the tempe-
rature of the temp. fuse reaches approximatery
142°C.
An open temp.
fuse indicates
overheating
of the magnetron
assembly.
If the temp.
fuse indicates
a open circuit,
replace the temp. fuse and check for restricted
air flow to the magnetron
through
the
opening in the chassis, especrally
the cooilng duct.
CONTROL
RELAY
(RLZI
TEST
Disconnect
the wire leads from the reiay rermrnals.
Connect
the ohmmeter
leads to the control
relay terminais
(2) and (3) of contacts
(A) or control
relay terminals
(4) and (5) of contacts
(B).
The meter should indicate
an open circuit
with power off and closed circuit
wrth cook pad touched.
In case improper
operation
is indicated,
replace the control
unit.
-
K
COOK
RELAY
(Rtlj
TEST
--
L
Disconnect
the wire
leads from
the relay
terminais
and connect
the ohmmeter
leads to the cook
relay terminals
(3) and (5).
The meter should indicate
an open circuit with power off and colsed circuit
with cook pad touched.
In case improper
operation
IS indicated,
replace the control
unit.
______~
STOP SWITCH
TEST
Isolate the stop switch and connect
the ohmmeter
leads to the common
(COM)
and normally
open
(NO)
termrnals
of the switch.
The meter
should
Indicate
an open circuit
with the open button
pushed and a closed circuit
wtth the open button
released,
In case improper
operation
is indicated,
repiace the stop switch.