5. Commissioning

5.2.2 Electrical connection

Connection
Signal
Potential-free relay
„Fault "
contact
Potential-free relay
"Metal 1"
contact
„Metal 2"
Potential-free relay
contact
24VDC switching
„24V Output"
output
„⊥ ⊥ ⊥ ⊥ "
Ground (GND)
„Outputs"
24VDC switching
outputs wired to
+24VDC
„24V"
24VDC Power
supply
„Inputs"
24V switching inputs
to ⊥
wired to +24VDC
Inputs to 24V
PE
N
L1
22
21
24
Ma ins
Fault
Function
Normal operation:
In case of a fault:
Normal operation:
In case of metal detection:
Special functions at mode Rapid (for Alarm devices) and
CONSENSE-D (Belt conv. Start/Stop)
Normal operation:
In case of metal detection:
Low-activ = yes (see 6.4.2.6):
Normal operation:
In case of metal detection:
Low-activ = no (see 6.4.2.6):
Normal operation:
In case of metal detection:
Special functions for bidirectinal pusher and for diverter
controller (Option)
Power supply for proximity switches and light barriers
Ground reference for the inputs IN1, IN2, LS and RST
LM:
LB:
LF:
Power supply for light barriers and proximity switches
Signal reference for outputs LF, LB and LM
Signal reference for inputs i0 .. i7
IN1
IN2
LS
RST
I0
I1
I2
I5
I7
I3,I4,I6, for special applications.
12 11 14
32
31 34
Metal 2
Metal 1
24V Output.
lights on metal detection
Metal lamp
Operation lamp
lights on test request (see also
chapter 7.2)
Fault lamp
lights in case of errors
1. Proximity switch input for distance measurement /
diverter flap
(NPN)
2. Proximity switch input for distance measurement /
diverter flap
(NPN)
Start Autotest (see chapter 6.4.2.7)
External Reset input
identically to IN1 but PNP
identically to IN2 but PNP
Pressure monitor
identically to LS but PNP
Free fall mode (Rapid XXXX): connection ot test push
button to activate the diverter unit.
LF LB LM
24V
Outputs
16
TecTronix-GENIUS-BA-CU-EN-3006.doc
Contact 21 and 24 closed
Contact 21 and 22 closed
Contact 31 and 32 closed
Contact 31 and 34 closed
Contact 11 and 12 closed
Contact 11 and 14 closed
0V DC to ⊥
24V DC to ⊥
24V DC to ⊥
0V DC to ⊥
IN1IN 2 LSR ST i7
i6
i5
Inputs
24V
24V
24V
24V
i4
i3
i2
i1
i0
Inputs