Martin Magnum 1200 User Manual

Martin Magnum 1200 User Manual

Flood light martin
Hide thumbs Also See for Magnum 1200:

Advertisement

P/N 35010028-D
Magnum 1200
Magnum 1800

user manual

Advertisement

Table of Contents
loading

Summary of Contents for Martin Magnum 1200

  • Page 1: User Manual

    P/N 35010028-D Magnum 1200 Magnum 1800 user manual...
  • Page 2: Table Of Contents

    Fog fluid types ......................... 18 Basic service..........................19 Cleaning..........................19 Fuse replacement ........................ 19 Optional accessories ....................... 20 Fitting the optional flying bracket..................20 Fitting the DMX decoder module (Magnum 1200) .............. 21 Troubleshooting ........................22 Specifications .......................... 23 Safety information...
  • Page 3: Safety Information

    Do not spill fluid over or inside the machine. If fluid is spilled, disconnect AC power and clean with a damp cloth. If fluid is spilled onto electronic parts, take the system out of service and contact Martin for advice. Safety information...
  • Page 4 • Do not remove the covers or attempt to repair a faulty machine. Refer any service not described in this manual to Martin. • Do not operate the machine if any parts are damaged, defective or missing. • Moisture and electricity do not mix. Do not aim smoke output at electrical connections or devices.
  • Page 5 P r e v e n t i n g b r e a t h i n g p r o b l e m s • A smoke machine can operate safely only with the smoke fluid it is designed for.
  • Page 6: Product Overview

    Magnum range is all about: state of the art technology, high quality and ruggedness. The Magnum 1200 delivers a heavy punch of fog. It’s tough and rugged enough to meet the demand of any night club. The Magnum 1800 is a high power fogger suitable for any install where a flexible machine is required.
  • Page 7: Product Details

    P r o d u c t d e t a i l s Heat (Red) / Ready (Green) indicators DMX address selection switches Remote / machine link sockets Main power switch Power inlet Hinged door to plug fluid compartment DMX input DMX through plug...
  • Page 8: Quick Start

    Locate the machine in a suitably large area with nothing in front of the smoke output. Fill the fluid tank with MARTIN-approved fluid (see page 18). The fluid compartment is opened by pulling outwards on the cover (pull using a finger in the round hole).
  • Page 9: Installation And Setting Up

    The machine requires: Magnum 1200: 3.9A at 230V (EU) or 7.4A at 120V (US) Magnum 1800: 5.2A at 230V (EU) or 8.6A at 120V (US) Check that the local AC voltage is appropriate, as indicated on the machine’s serial number label.
  • Page 10: Setting Up

    If DMX control is being used, connect the machine to the DMX line (see page 16). The optional DMX module is required to use the Magnum 1200 with DMX. Connect the remote to the REMOTE IN socket on the back panel.
  • Page 11: Final Checks

    3 • the smoke fluid is one of the genuine Martin fluids listed under “Smoke fluid options” on page 18 • the machine is electrically grounded (earthed) •...
  • Page 12: Control Settings

    Control settings O v e r v i e w Output level / timer programming knob Machine ready to fog Machine heating light light Fog / Timer engage button Timer On light Timer Off light Timer set button The unit is controlled using the remote control. You can control it in these ways: •...
  • Page 13: Setting The Automatic Timer

    S e t t i n g t h e A u t o m a t i c T i m e r The Automatic Timer allows you to set the machine to keep producing timed bursts of fog without anyone having to press any buttons. You need to set two times: the run/on time during which the machine will produce fog, and the wait/off time during which the machine will idle.
  • Page 14: Disabling Timer Mode

    D i s a b l i n g t i m e r m o d e If you wish to simplify the remote control, you can disable the timer function. This means that a short press on the FOG button will just produce a short burst of fog and the timer will not be enabled.
  • Page 15: What The Status Lights Mean

    W h a t t h e s t a t u s l i g h t s m e a n The four lights on the remote have the following functions. The red “HEAT” light and the green “READY” light are also duplicated on the top of the machine itself. HEAT+READY meaning no lights...
  • Page 16: Dmx Control

    Any controller meeting the DMX-512 standard may be used to control and program the fog output of the Magnum smoke machine. The Magnum 1200 requires the optional DMX interface module to enable DMX operation. C o n n e c t i o n The Magnum smoke machine provides a 3-pin XLR plug and socket on the rear panel for DMX connection.
  • Page 17: Setting The Dmx Address

    S e t t i n g t h e D M X a d d r e s s Each unit on a DMX system must be allocated an address so that the DMX controller can send separate commands to the unit. On the Magnum smoke machine, the DMX address is set using the bank of switches (“dip switches”) on the back panel next to the DMX connectors.
  • Page 18: Fog Fluid Types

    Fog fluid types The following types of Martin/Jem fog fluid are suitable for use in this machine. Each produces a different effect as described below. Martin supplies high quality fog fluids that are based on ultra-pure deionized water. Use only the following genuine Martin/Jem fog fluids.
  • Page 19: Basic Service

    Before servicing the Magnum smoke machine, read and observe all the precautions listed in “Safety information” on page 3. Any service not described in this section must be carried out by a Martin service technician. C l e a n i n g...
  • Page 20: Optional Accessories

    Optional accessories F i t t i n g t h e o p t i o n a l f l y i n g b r a c k e t The optional flying bracket is fixed to the underside of the machine using 4 M4 taptite screws, supplied with the bracket.
  • Page 21: Fitting The Dmx Decoder Module (Magnum 1200)

    F i t t i n g t h e D M X d e c o d e r m o d u l e ( M a g n u m 1 2 0 0 ) The optional DMX decoder replaces the blanking plate on the rear of the Magnum 1200. DANGER! Disconnect the power supply before removing the blanking plate. Live parts inside! 1.
  • Page 22: Troubleshooting

    Troubleshooting Problem Probable cause(s) Suggested remedy Machine not at operating Wait 10 to 15 minutes temperature Machine will not produce fog Ensure mains power switch Machine not powered up or when remote control Fog on, enable heaters by heaters disabled button pressed pressing FOG Output level control set to...
  • Page 23: Specifications

    Specifications M a g n u m 1 2 0 0 M a g n u m 1 8 0 0 P h ys i c a l Length ..............450mm......500mm Width ..............205mm......232mm Height..............244mm......266mm Dry weight .............. 8.2Kg....... 9.9Kg P e r f o r m a n c e Effect coverage ..........
  • Page 24 Ducting system Magnum series ............P/N 92625009 O r d e r i n g i n f o r m a t i o n Martin Magnum 1200 smoke machine 120V ........P/N 92228910 Martin Magnum 1200 smoke machine 230V ........P/N 92228911 Martin Magnum 1800 smoke machine 120V ........P/N 92229010...
  • Page 25 Notes Notes...
  • Page 26 Notes...
  • Page 28 Martin Professional A/S,Olof Palmes Allé 18, DK-8200,Aarhus N Phone: +45 87 40 00 00 Internet: www.martin.com...