  • Page 1 READ AND SAVE THESE INSTRUCTIONS P/N 35010042-B user manual...
  • Page 2: Dimensions

    Dimensions All dimensions are in millimeters ™ ™ Dimensions...
  • Page 3 The Martin logo, the Martin name and all other trademarks in this document pertaining to services or products by Martin Professional or its affiliates and subsidiaries are trademarks owned or licensed by Martin Professional or its affiliates or subsidiaries.
  • Page 4: Table Of Contents

    Contents Dimensions ..........................2 Contents ............................ 4 Safety information ........................5 Product overview ........................8 Product description ........................ 8 Features at a glance ......................8 Product details ........................9 Quick Start ..........................12 Setting up ..........................12 Making fog ........................... 12 Installation and setting up .......................
  • Page 5: Safety Information

    • defective, wet, or show signs of overheating, stop using the machine and contact Martin™ Service for assistance. If the supply cord is damaged, it must be replaced by a special cord or assembly available from the manufacturer or its service agent.
  • Page 6 Do not spill fluid over or inside the machine. If fluid is spilled, disconnect AC power and clean with a damp cloth. If fluid is spilled onto electronic parts, take the machine out of service and contact Martin™ for advice. •...
  • Page 7 If you have any questions about how to install, operate or service the fixture safely, please contact your Martin™ distributor (see www.martin.com/distributors for details) or call the Martin™ 24-hour service hotline on +45 8740 0000, or in the USA on 1-888-tech-180.
  • Page 8: Product Overview

    Congratulations on your purchase of a JEM ZR series™ product from Martin™. Details of the full range of Martin™ products are available on our website at www.martin.com. F e a t u r e s a t a g l a n c e Flying/hanging bracket as standard •...
  • Page 9: Product Details

    P r o d u c t d e t a i l s Integral hanging ZR25™ bracket Fluid container Fluid pipe connection Removable control panel DMX input Mains fuse and output Mains power Mains power switch connector If suspending overhead: Loop safety cable under hanging bracket and secure...
  • Page 10 ZR35™ Integral hanging bracket Fluid container Fluid pipe connection Removable control panel Mains power DMX input switch and output Mains fuse Mains power connector If suspending overhead: Loop safety cable under hanging bracket and secure Fog output nozzle WARNING! High temperature vapour and surfaces Product overview...
  • Page 11 ZR45™ Integral hanging bracket Fluid container Fluid pipe connection Removable control panel Mains power DMX input switch and output Mains fuse Mains power connector If suspending overhead: Loop safety cable under hanging bracket and secure Fog output nozzle WARNING! High temperature vapour and surfaces Product overview...
  • Page 12: Quick Start

    Quick Start You are no doubt eager to switch on the machine and try it out by making a lot of fog. This section tells you how to do that. However, please also make the time to read the safety and servicing instructions in the remainder of this manual. S e t t i n g u p Locate the machine in a suitably large area with nothing in front of the fog output.
  • Page 13: Installation And Setting Up

    Installation and setting up DANGER! DO NOT operate the machine until you have read and observed all the precautions listed under “Safety information” on page 5. L o c a t i o n The JEM ZR series™ machines are designed to be located on the floor or may be suspended using the fitted flying bracket.
  • Page 14: Setting Up

    Check that the local AC voltage is appropriate, as indicated on the machine’s serial number label. If your AC voltage is outside the appropriate range, do not use the machine. Contact Martin™ Service for assistance. S e t t i n g u p Fill the fluid tank with a suitable JEM™...
  • Page 15: Control Settings

    Control settings O v e r v i e w The digital display panel on the rear of the machine allows you to configure it using option menus. The digital display may be removed from the unit and used as a remote control by removing the two handwheel bolts either side of the display.
  • Page 16: Setting The Timer

    If you want to temporarily change the fog density, do not press Enter. The fog setting will go back to its stored value next time the machine is powered up. This applies to all options. S e t t i n g t h e T i m e r Set the RUN TIME and OFF TIME values from the menu.
  • Page 17: Priming The Machine After Fluid Out

    Use the Up/Down buttons to select RECEIVE (slave unit) or SEND (master unit). Press the Enter button to store the link setting. The machine should be set to SEND only if it is running as a master. If running as a slave, stand-alone or DMX controlled it should be set to RECEIVE. If a machine set to SEND is connected to an active DMX system, the DMX will be corrupted causing flickering of lights and other strange symptoms.
  • Page 18 The factory settings are: option setting FOG LEVEL 50% TIMER ON 10 seconds TIMER OFF 20 seconds RUN MODE STANDBY 001 BACK LIGHT NORM LINK MODE RECEIVE PRIME NO TEMPERATURE* NORM *ZR45 Only Control settings...
  • Page 19: Dmx Control

    DMX connection. For best results, use cable designed for high speed digital data transmission. Suitable DMX cable is available from your Martin™ dealer. D M X f u n c t i o n s The JEM ZR series™ address setting must match the DMX address allocated to it on your controller.
  • Page 20: Fog Fluid Types

    Fog fluid types The JEM ZR series™ machines must only be used with the JEM™ fluids listed below. Martin™ supplies high quality fog fluids that are based on ultra-pure deionized water. No other fluid is suitable for use. R e g u l a r D J F l u i d ( D J m i x ) Regular DJ fluid is an economical fluid that gives a good, medium density smoke well-suited for atmospheric effects.
  • Page 21: Basic Service

    120 V = 20 AT/125V 230 V = T12.5 AT/250V Replace fuse only with one of exactly the same size and rating. Contact Martin™ Service if the fuse blows repeatedly. To replace the internal fuse, disconnect the power cord from the supply, unscrew the screws holding the top cover of the unit and remove the cover.
  • Page 22: Troubleshooting

    Troubleshooting Problem Probable cause(s) Suggested remedy Machine not at operating Wait until HEAT message no temperature longer shown Machine will not produce fog FOG option set to 0 Increase setting when control panel set to Machine in timer mode and CONTINUOUS or fog button Increase setting TIMER ON set to 0...
  • Page 23: Status Messages

    SETTINGS menu CALIBRATION The machine has detected an error with its calibration ERROR settings and will not operate. Call Martin™ Service. SYSTEM The machine has detected an error in the temperature sensor ERROR and will not operate. Call Martin™ Service.
  • Page 24: Specifications

    Specifications P h y s i c a l ZR25 Length ......................485 mm Width ......................335 mm Height ..........242mm (333mm including hanging bracket) Dry weight ....................11.2 kg ZR35 Length ......................590 mm Width ......................395 mm Height ..........264mm (351mm including hanging bracket) Dry weight ....................
  • Page 25 A c c e s s o r i e s Analogue Remote Control, JEM ZR series™ machines ....P/N 92765044 Ducting System, JEM ZR25™ ............P/N 92625012 Ducting System, JEM ZR35™ ............P/N 92625013 Ducting System, JEM ZR45™ ............P/N 92625014...
  • Page 26 O r d e r i n g i n f o r m a t i o n JEM ZR25™ machine US model 120V ..........P/N 92215330 JEM ZR25™ machine EU model 230V ..........P/N 92215320 JEM ZR35™ machine US model 120V ..........P/N 92215350 JEM ZR35™...
  • Page 27 Electronic Equipment), as amended by Directive 2003/108/EC, where applicable. Help preserve the environment! Ensure that this product is recycled at the end of its life. Your supplier can give details of local arrangements for the disposal of Martin products. Specifications...