Martin Magnum 1500 User Manual

Compact and efficient fog generator

Advertisement

Magnum 1500
user manual

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Magnum 1500 and is the answer not in the manual?

Questions and answers

Summary of Contents for Martin Magnum 1500

  • Page 1 Magnum 1500 user manual...
  • Page 2 All dimensions are in millimeters Ø13 ©2005 Martin Professional A/S, Denmark. All rights reserved. No part of this manual may be reproduced, in any form or by any means, without permission in writing from Martin Professional A/S, Denmark. P/N 35000160, Rev. A...
  • Page 3: Table Of Contents

    Features ..........5 Magnum 1500 overview ....... . 6 Safety information .
  • Page 4 This page intentionally left blank.
  • Page 5: Introduction

    NTRODUCTION Thank you for selecting the Magnum 1500. The Magnum 1500 is a compact and efficient fog generator for semi- professional use. It uses a water-based fluid with an aluminum and copper heat exchanger to create a white fog for entertainment and theatrical use.
  • Page 6: Magnum 1500 Overview

    Remote control out Timer Service port Ready Remote control in Heat Fog fluid level check window 10. Fog fluid bottle 11. Timer dial Level 12. Status indicator LEDs 13. Fog output level dial 14. Instant fog button Magnum 1500 user manual...
  • Page 7: Safety Information

    If you have questions about how to operate the machine safely, please contact a Martin distributor for assistance or call the Martin 24-hour service hotline on +45 70 200 201.
  • Page 8 • Allow the machine to cool for at least 20 minutes before handling or opening – the machine becomes hot during use. • Use only genuine Martin or JEM fluid in the machine. • Never attempt to bypass the thermostatic switch or fuses. Always replace defective fuses with ones of the specified type and rating.
  • Page 9: Unpacking

    • Power cable • User manual The Magnum 1500 is supplied with the fluid bottle empty to avoid spillage during shipment. The fluid bottle must be filled before using for the first time (see “Filling the fluid bottle” on page 17).
  • Page 10: Installation

    Do not install the Magnum 1500 at an angle of more than 30° up or down from horizontal. To avoid fluid leakage, the fluid bottle filler cap must always point upwards.
  • Page 11 Placing on a horiz ontal su rface If preferred, the Magnum 1500 can be installed on a level horizontal surface, resting either on its rubber feet or on its mounting bracket. The mounting bracket can be used to support the machine at an angle. If the machine is to be placed on a horizontal surface: •...
  • Page 12 Repositioning the fluid bottle Resting the Magnum 1500 on its mounting bracket means operating it upside-down. This does not affect operation, but to avoid leaks the fluid bottle must also be repositioned so that the filler cap remains at the top.
  • Page 13: Ac Power

    • US model (120 V, 60Hz for 105-115 VAC power supplies) • EU model (230 V, 50Hz for 220-245 VAC power supplies) The Magnum 1500 is supplied set up to match local voltage and frequency settings. The factory default setting is shown on the serial number label.
  • Page 14: Installing Control Hardware

    Multiple linking with a remote control unit The Magnum 1500’s multiple linking feature allows more than one machine to be controlled using the remote control. If machines are linked, all machines receive the same instructions from the remote control and behave identically.
  • Page 15 2. Connect the remote control unit to the IN socket on the first Magnum 1500 on the link. 3. Lead a suitable cable from the OUT socket on the first Magnum 1500 to IN on the next Magnum 1500. If more machines are to be operated together, continue linking them, connecting output to input.
  • Page 16: Operation

    • The pump has been primed if the machine is new or has not been used for some time (see “Priming the pump” on page 18). For the Magnum 1500 to work, the remote control must be connected, or the machine must be linked to an active control device (a DMX controller or another Magnum 1500 on a multiple link).
  • Page 17: Checking Fluid Level

    Always disconnect the machine from power before working with the fluid system. The fluid bottle must be removed from the machine for filling. Use only Martin or JEM fog fluid of the following types: • Regular DJ Fluid (DJ mix) • Pro Smoke Fluid (ZR mix) To fill the fluid bottle: 1.
  • Page 18: Priming The Pump

    P r i m i n g t h e p u m p The pump must be primed when the Magnum 1500 is used for the first time, or if it has not been used for an extended period.
  • Page 19: Remote Control Operation

    Note that the Magnum 1500 is not designed to give continuous output at the highest levels. If you set the output level to 10 (maximum), output will be interrupted after approximately 50 seconds while the machine re- heats.
  • Page 20 5. Press the plastic reset switch to reset the thermal protection cutout. 6. Replace all covers and screws before reapplying power. If the thermal cutout operates repeatedly, contact your Martin dealer for service. Magnum 1500 user manual...
  • Page 21: Service And Maintenance

    R e p l a c i n g t h e m a i n f u s e The Magnum 1500 uses a time-delay fuse for protection against current overload. An indication that the fuse may have blown is that the indicator...
  • Page 22 5. The main fuse is located in a fuseholder on the control circuit board. Gently pull the circuit board out a few centimeters to give access to the fuseholder. Magnum 1500 user manual...
  • Page 23: Uploading New Software

    7. Replace the fuse with one of the same type. The fuse rating is listed on the serial number label and in “Magnum 1500 specifications” on page 34 of this manual. 8. Replace the fuseholder cover and any connectors.
  • Page 24: Troubleshooting

    Machine not ready but no fog output when to change from red to machine is fired using orange or green Fit termination plug to No DMX termination last device on DMX link Airlock in pump Prime pump Magnum 1500 user manual...
  • Page 25: Service Codes

    Ready Heat Level If the Magnum 1500 flashes a service code, reset the machine by powering off and on again. If the code persists, refer to your Martin dealer. Service code Message One short blink every second Overheating error or calibration (approx.)
  • Page 26: Optional Ducting Adapter

    PTIONAL DUCTING ADAPTER Fog/smoke ducting gives flexibility in directing fog output. It can also allow you to install the Magnum 1500 in a safe location with convenient access for refilling, service, etc. The Magnum 1500 can be connected to standard 4-inch (102 mm) fog/smoke ducting using an adapter.
  • Page 27: Magnum 1500 Dmx Interface Module

    1500 DMX AGNUM INTERFACE MODULE The Magnum 1500 can be controlled using a DMX controller on a serial data link if a DMX interface module is installed. This module is available separately as an optional accessory (DMX Interface Module, Magnum 1500, P/N 91612000).
  • Page 28 DMX interface connector must face towards the locking tab on the circuit board connector. The wiring connector is an easy sliding fit. If you need to force it, you may be trying to insert it the wrong way round. Magnum 1500 user manual...
  • Page 29 485 applications. Your Martin dealer can supply suitable high quality cable in various lengths. The Magnum 1500’s XLR data sockets are wired with pin 1 to ground, pin 2 to signal - (cold), and pin 3 to signal + (hot). This is the standard pin assignment for DMX devices.
  • Page 30 To connect a 5-pin XLR output to the Magnum 1500, use a 5-pin male to 3-pin female XLR adaptor cable (P/N 11820005). To connect the Magnum 1500 to a 5-pin XLR input, use a 3-pin male to 5-pin female adaptor cable (P/N 1820004).
  • Page 31 4. For each machine, set the DMX address by setting the DIP-switch pins 1 through 9 to the ON (1) or OFF (0) position as listed in the table on the next page. As an example, channel 101 is highlighted in the table. Magnum 1500 DMX interface module...
  • Page 32: Dmx Operation

    93 125 157 189 221 253 285 317 349 381 413 445 477 509 94 126 158 190 222 254 286 318 350 382 414 446 478 510 95 127 159 191 223 255 287 319 351 383 415 447 479 511 Magnum 1500 user manual...
  • Page 33: Dmx Controller Operation

    The Magnum 1500 is ready for operation after approximately 10 minutes. Set the level on the Magnum 1500’s DMX control channel to zero to cut fog output to zero. Increase the level on the machine’s DMX control channel to increase the level of fog output.
  • Page 34: Magnum 1500 Specifications

    PC/uploader ..........serial port Magnum 1500 user manual...
  • Page 35 Magnum 1500 (230 V, 50 Hz EU model) ....P/N 91120000 Magnum 1500 (110 V, 60 Hz US model) ....P/N 91120100...
  • Page 36 Martin Professional A/S • Olof Palmes Allé 18 • 8200 Aarhus N • Denmark Tel: +45 8740 0000 • Internet: www.martin.com...

Table of Contents