Lcd/Inverter Settings - DFI G5M300-P User Manual

Rev. a+ system board
Table of Contents

Advertisement

2
Hardware Installation

2.4.4 LCD/Inverter Settings

JP6 is used to select the power supplied to the LCD panel and to
select the inverter's on/off level.
LCD Panel
Power Select
Inverter On/Off
Level Select
26
2
1
1-3 On: 5V
2
1
2-4 On: 5V
Important:
Before powering-on the system, make sure JP6's setting
matches the LCD panel's specification. Selecting the incorrect
voltage will seriously damage the LCD panel.
JP6
12
12
2
1
11
11
3-5 On: 3.3V
12
2
12
1
11
11
4-6 On: 12V
12
2
1
11
12
2
1
11
7-9 On: 12V