LCD/Inverter Settings

JP7 is used to select the power supplied to the LCD panel and to
configure the inverter.
Panel Power
5 V
3.3V
12V
Important:
Before powering-on the system, make sure JP7's setting
matches the LCD panel's specification. Selecting the incorrect
voltage will seriously damage the LCD panel.
LCD/Inverter Settings - JP7
Inverter On Level
1-3 On
5 V
2-4 On
3-5 On
12V
4-6 On
7-9 On
Hardware Installation
JP7
Inverter On/Off Select
Active Low
8-10 On
Active High
10-12 On