COPY OF THE LIGHTING PLATE INSTRUCTIONS
FOR YOUR SAFETY READ BEFORE LIGHTING
This appliance must be installed in accordance with local codes, if any; if not,
follow the current CAN1-B149/ANSI Z 223.1 (Australia: AG601, New Zealand: NZS 5261)
WARNING: If you do not follow these instructions exactly, a fire or explosion may result
causing property damage, personal injury or loss of life. Improper installation, adjustment,
alteration, service or maintenance can cause injury or property damage. Refer to the
owner's information manual provided with this appliance. For assistance or additional
information consult a qualified installer, service agency or gas supplier.
A) BEFORE LIGHTING smell all around the appliance
area for gas. Be sure to smell next to the floor
because some gas is heavier than air and will
settle on the floor.
WHAT TO DO IF YOU SMELL GAS
- Do not try to light any appliance
- Do not touch any electric switch, do not use any
phone in your building
- Immediately call your gas supplier from a
neighbors phone. Follow the gas supplier's in-
structions.
- If you cannot reach your gas supplier, call the
fire department.
CAUTION: Hot while in operation. Do not touch. Severe Burns may result. Due to high surface
temperatures keep children, clothing and furniture, gasoline and other liquids having
fammable vapors away. Keep burner and control compartment clean. See installation and
operating instructions accompanying appliance.
STOP! Read the safety information above on this label.
1)
Plug the power cord into a power outlet.
2)
Press and release the ON/OFF button once to
start the unit.
1)
Press the ON/OFF button once.
DO NOT REMOVE THIS INSTRUCTION PLATE
Masport PG121/PG131 Zero Clearance Room Sealed Gas Fireplace
B) Do not use this appliance if any part has been
under water. Immediately call a qualified service
technician to inspect the appliance and to replace
any part of the control system and any gas control
which has been under water.
This appliance needs fresh air for safe operation
and must be installed so there are provisions for
adequate combustion and ventilation air.
LIGHTING INSTRUCTIONS
3)
After approximately 3 seconds the spark
ignition system will spark for 40 seconds to
light the main burner.
4)
If the main burner does not light, check the
gas and reset the unit.
TO TURN OFF GAS APPLIANCE
2)
Turn off all electric power to the unit if
service is to be performed.
OPERATING INSTRUCTIONS
INSTRUCTIONS
Any maintenance required accessing the
glass door of the unit must be performed by
an authorized service person.
1) Always unplug the power cord before
cleaning. For relighting, refer to lighting
instructions. Keep the burner and control
compartment clean by brushing and vacu-
uming at least once a year. When cleaning
the logs, use a soft clean brush as the logs
are fragile and easily damaged.
2) Clean glass (never when unit is hot), appli-
ance, louvres, and door with a damp cloth.
Never use an abrasive cleaner. The gold
louvres (and optional gold door) may be
scratched if abrasives are used to clean
them.
The heater is finished in a heat resistant
paint and should only be refinished with
heat resistant paint (not with wall paint).
Masport uses StoveBright Paint - Metallic
Black #6309.
3) Make a periodic check of burner for proper
position and condition. Visually check the
flame of the burner periodically, making
sure the flames are steady; not lifting or
floating. If there is a problem, call an author-
ized service person.
4) The appliance and flueing system must be
inspected before use, and at least annual-
ly, by an authorized field service person, to
ensure that the flow of combustion and
ventilation air is not obstructed.
During the annual service call, the burners
should be removed from the burner tray
918-332
and cleaned. Replace the embers - do not
block the pilot or burner ports.
5) Keep the area near the appliance clear and
free from combustible materials, gasoline
and other flammable vapours and liquids.

General Flue Maintenance

Conduct an inspection of the flueing system
semi-annually. Recommended areas to inspect
as follows:
1) Check the Flueing System for corrosion in
areas that are exposed to the elements.
These will appear as rust spots or streaks,
and in extreme cases, holes. These com-
ponents should be replaced immediately.
2) Remove the Cap, and shine a flashlight
down the Flue. Remove any bird nests, or
other foreign material.