1) When selecting a location for your stove,
ensure that the clearances are met as
outlined on page 9.
2) Provide adequate clearances for servic-
ing.
3) The appliance must be installed on a flat,
solid, continuous surface (e.g. wood, met-
al, concrete). This may be the floor, or
raised up on a platform to enhance its
visual impact. If the appliance is going to be
installed on carpeting, combustible linole-
um tile or other combustible material other
than wood flooring, the appliance must be
installed on a metal or wood panel extend-
ing the full width and depth of the appli-
ance.
4) The Room Sealed Gas Fireplace can be
installed as follows:
Model # Position
A )
PG121: See Thru
B)
PG131: Pier
C)
PG121LC: Left Corner
D)
PG121RC: Right Corner
5) This appliance is Listed for bedroom instal-
lations when used with a Listed Millivolt
Thermostat. Some areas may have further
requirements, check local codes before
installation.
6) The PG121/PG121LC/PG121RC/PG131
Room Sealed Gas Fireplace is approved
for alcove installations, which meet the
clearances listed on this page.
7) We recommend that you plan your instal-
lation on paper using exact measurements
for clearances and floor protection before
actually installing this appliance. Have a
authorized inspector, dealer, or installer
review your plans before installation.
Note: For Exterior Flue
Termination
Locations see page 12.
.
8
A) PG121 - See Thru
B) PG131 - Pier
C) PG121LC - Left Corner
D) PG121RC - Right Corner