Absolute Maximum Ratings-Adsst-73360Lar; Esd Caution - Analog Devices ADSST-EM-3040 Manual

Powerful energy meter chipset
Table of Contents

Advertisement

ADSST-SALEM-3T
ABSOLUTE MAXIMUM RATINGS—ADSST-73360LAR
(T
= 25°C unless otherwise noted)
A
Table 8.
Parameter
AVDD, DVDD to GND
AGND to DGND
Digital I/O Voltage to DGND
Analog I/O Voltage to AGND
Operating Temperature Range
Storage Temperature Range
Maximum Junction Temperature
Thermal Impedance θ
(SOIC)
JA
Stresses above those listed under Absolute Maximum Ratings
may cause permanent damage to the device. This is a stress
rating only; functional operation of the device at these or any
other conditions above those listed in the operational sections
of this specification is not implied. Exposure to absolute
maximum rating conditions for extended periods may affect
device reliability.
.

ESD CAUTION

ESD (electrostatic discharge) sensitive device. Electrostatic charges as high as 4000 V readily accumulate on the
human body and test equipment and can discharge without detection. Although this product features
proprietary ESD protection circuitry, permanent damage may occur on devices subjected to high energy
electrostatic discharges. Therefore, proper ESD precautions are recommended to avoid performance
degradation or loss of functionality.
Rating
–0.3 V to +4.6 V
–0.3 V to +0.3 V
–0.3 V to DVDD + 0.3 V
–0.3 V to AVDD
0°C to +70°C
–65°C to +150°C
150°C
75°C/W
Rev. 0 | Page 14 of 24