Start Unit Request Failed; Index - Acer Altos 12000 Series User Manual

Table of Contents

Advertisement

5.5.2

Start unit request failed

The BIOS was unable to send a Start Unit Command to the device. Run the
SCSISelect utility and disable Send Start Unit Command for the device.
Time-out failure during SCSI Inquiry command!
or
Time-out failure during SCSI Test Unit Ready command!
or
Time-out failure during Start Unit command!
An unexpected time-out occurred. Check SCSI bus termination. Try disconnecting
the SCSI peripheral cables from the SCSI controller and then starting the
computer. If the computer successfully restarts, check SCSI bus termination and
cable connections. One of the devices on the SCSI bus may be defective.

Index

clxvii

Advertisement

Table of Contents
loading