H O W T O R E S E T T H E B R E A K E R
If all electronic sensors fail or are not adjusted properly due to
heavy gates, off-track gate, or obstructed gate path, the breaker
.
will kick-out. Reset the breaker by pressing the reset button
located on the bottom left corner of the control board.
If the gate is not moving in any direction be sure to check all of
the LED displays on the control board. If the board power or
charging power LEDs are "ON", change the corresponding
fuse on the top left corner of the board.
The breaker reset is located at
the bottom left corner of the
control board as shown
H O W T O C H E C K T H E F U S E S
Replace fuse with
1.5A - 250V fuse
Robo Fuse
(Part # Q162)
WARNING
To prevent SERIOUS INJURY or DEATH from a moving gate:
ALWAYS disconnect the battery before resetting the breaker or
injury could occur as the gate starts.
CAUTION
To AVOID damaging the control board, replace fuses ONLY
with same type and rating specified above.