Error messages

Error:
Lamp Startup Fail
Temperature Sense Error
Lamp Too Hot Power Off
Lamp Too Hot Low Power
Maintenance Fixture
Memory Initial Fail
CPU-B Error, CPU-C Error,
CPU-D Error
Pan Reset Error
Pan Encode Error
Tilt Reset Error
Tilt Encode Error
Shutter Reset Fail
Dimmer Reset Fail
Color Reset Fail
Gobo Reset Fail
36
Appears when:
No LEDs sensed, possible wiring damage.
Damage to temperature sensor on PCB
reported.
Internal temperature higher than 110° C
detected. Ensure that fixture is adequately
ventilated. Check that ambient temperature
does not exceed 40° C. Possible fan or
temperature sensor damage. Contact Martin
support.
Internal temperature higher than 105º C
detected. Fixture runs at reduced power level.
Service countdown timer has reached zero.
Check whether fixture requires maintenance
such as cleaning, then reset countdown timer
in Fixture Information menu.
Damaged memory IC. Contact Martin support.
Board, processor or fixture wiring is damaged.
Contact Martin support.
These can appear when powering on or
resetting the fixture and can indicate damage
to sensors or components. If error persists,
contact Martin support.