4 - DMX XLR input/output sockets
3-pin and 5-pin XLR sockets are provided for DMX input and output
(throughput).
5 - Fuse
The T 6.3 A fixture fuse is located in a fuseholder next to the power
input/output connectors.
6 - Mains power input
A blue Neutrik PowerCon socket is provided to connect the fixture to AC mains
power.
7 - Mains power throughput
See 'Safety information' on page 4. The light-grey Neutrik PowerCon socket
can be used to supply power to other fixtures only if the power input cable is
replaced as directed in this manual and safety limits are respected.

Control data link

A DMX 512 data link is required in order to control the fixture via DMX. The
fixture has 3-pin and 5-pin XLR connectors for DMX data input and output.
The number of daisy-chained fixtures is limited by the number of DMX
channels required by the fixtures in relation to the maximum 512 channels
available in one DMX universe. Note that if independent control of a fixture is
required, it must have its own DMX channels. Fixtures that are required to
behave identically can share the same DMX address and channels. To add
more fixtures or groups of fixtures when the above limit is reached, add a DMX
universe and another daisy-chained link.