Display Messages - Martin MAC 550 Profile User Manual

Hide thumbs Also See for MAC 550 Profile:
Table of Contents

Advertisement

D
ISPLAY MESSAGES
Message

(Reset)

(Serial reset)



(Lamp error)

(Memory error)

(Short error)

(Base temperature error)

(Head temperature error)

(Feedback error pan)

(Feedback error tilt)

(Feedback error pan/tilt)

(Pan time-out)

(Tilt time-out)

(Focus time-out)

(Zoom time-out)

(Gobo wheel time-out)

(Gobo wheel rotation
time-out)

(Animation wheel position
time-out)

(Animation wheel rotation
time-out)




38
Appears when...
... the fixture is indexing effects at startup.
... the fixture has received a reset command
from the controller.
... the effects have been indexed and are
moving to their default positions.
...the lamp access cover is not fully closed.
... the lamp doesn't ignite within 10 minutes of
receiving the 'Lamp ON' command. Likely
reasons are a missing or defective lamp, or
insufficient AC voltage.
...the EEPROM memory cannot be read.
... the fixture detects the lamp is ON but no
'Lamp ON' command has been received. This
can occur if the lamp relay is stuck or if the
lamp-power feedback circuit fails. The fixture
may be operated but remote lamp on/off may
be affected.
... there is a fault with the temperature sensor
in the base or head.


...pan (
), tilt (
) or both (
feedback circuits are malfunctioning. It will still
be possible to operate the fixture, but it
switches into a "safe" mode where maximum
speed is reduced, thus preventing the fixture
from losing track of its home position (losing
step).
...the electric indexing circuit is
malfunctioning. The fixture will, after the
time-out, establish a mechanical stop, and
continue to work normally.
...the magnetic-indexing circuit malfunctions
(e.g. sensor defective or magnet missing).
After the time-out, the effect in question stops
in a random position.
...there is an onboard RAM memory error.
...there is an onboard programming error.
...light sensor 1 is in error status.
---there is a thermoswitch error or a jumper on
PL47 error.
Table 4: Display messages
MAC 550 Profile
What to do
Wait for reset to complete.
Wait for reset to complete. Set


!
accidental reset commands.
Wait a few moments.
Verify that the lamp access cover is locked
in place.
Check the lamp. Check that the voltage
and frequency settings match the local
supply.
Contact Martin service personnel for
assistance.
Contact Martin service personnel for
assistance.
Contact Martin service personnel for
assistance.

)
Contact Martin service personnel for
assistance.
Reset fixture again. Contact Martin
service personnel if problem continues.
Reset fixture again. Contact Martin
service personnel if problem continues.
Contact Martin service personnel for
assistance.
Contact Martin service personnel for
assistance.
Contact Martin service personnel for
assistance.
Contact Martin service personnel for
assistance.

to
to prevent

Hide quick links:

Advertisement

Table of Contents
loading