AC power

Warning! Read 'Safety information' on page 4 before
connecting the fixture to AC mains power.
Warning! The mains power input cable supplied with the
fixture is rated 6 A and can supply only one fixture with
mains power. Do not connect any device to the fixture's
MAINS OUT power throughput socket when using this input
cable. If you want to connect other fixtures to the MAINS
OUT socket, see 'Linking fixtures to power in a chain' on
page 13.
For protection from electric shock, the fixture must be grounded
(earthed). The power distribution circuit must be equipped with a
fuse or circuit breaker and ground-fault (earth-fault) protection.
Socket outlets or external power switches used to supply the
fixture with power must be located near the fixture and easily
accessible so that the fixtures can easily be disconnected from
power.
Do not insert or remove live Neutrik PowerCon connectors to apply or cut
power, as this may cause arcing at the terminals that will damage the
connectors.
Do not use an external dimming system to supply power to the fixture, as this
may cause damage to the fixture that is not covered by the product warranty.
The fixture can be hard-wired to a building electrical installation if you want to
install it permanently, or a power plug (not supplied) that is suitable for the
local power outlets can be installed on the power cable.
If you install a power plug on the power cable, install a grounding type
(earthed) plug with integral cable grip that is rated minimum 250 V, 6 A. Follow
the plug manufacturer's instructions and connect the wires in the power cable
as shown in this table:
US system
EU system
The fixture has an auto-ranging power supply that accepts AC mains power at
100-240 V at 50/60 Hz. Do not apply AC mains power at any other voltage or
frequency to the fixture.
12
Live or L
Neutral or N
Black
Brown
RUSH MH 1 Profile User Manual
Earth, Ground or
White
Blue
Green
Yellow/green