3.5

seTup-FunCTiOns

SETUP-function
Upslope current dependency (*C)
Downslope current dependency (*C)
TIG Antifreeze (*C)
MMA Antifreeze (*C)
VRD (*C)
2T downslope cut off
Tacking automatics
Limitation of rate of current rise with
high currents
MMA/TIG method selection with
remote control (C*)
SearchArc On/Off
Current freeze function
Memory channel selection with Up/
Down buttons (C*)
Activation of the Plus/Minus buttons
(C*)
Water cooler flow guard (C*)
Water cooler automatic control (C*)
Water cooler temperature guard (C*)
Automatic remote control device
recognition (C*)
Tail arc
Display
*C = Common: applies to all memory channels
Factory setting with a grey background
A1
ON
The upslope time is determined by the current.
OFF
The upslope time remains as set.
A2
ON
The downslope time is determined by the current (the
user may set the slope gradient).
OFF
The downslope time remains as set.
A3
ON
TIG Antifreeze on.
OFF
TIG Antifreeze off.
A4
ON
MMA Antifreeze on.
OFF
MMA Antifreeze off.
A7
ON
VRD mode: idle voltage < 35 V
OFF
Normal idle voltage
A8
ON
In 2T mode, cut off the downslope with a quick push of
the start button.
OFF
Quick push has no effect.
A9
ON
If welding has lasted less than 3 seconds, no downslope
when welding is stopped.
OFF
Tacking automatics off.
A10
ON
If the current is over 100 A and UpSlope is 0.0 sec., there is
a 0.2-second slope from half the welding current.
OFF
Current rises directly to maximum.
A12
ON
TIG = the start of remote control scale.
MMA = the end of the scale.
OFF
Remote control as a normal current regulator.
A13
ON
SearchArc on.
OFF
SearchArc off.
A14
ON
During the downslope, the current can be 'frozen' at a
certain level by pushing the start button.
OFF
Freeze function off.
A15
ON
The Plus/Minus buttons on the remote control can be used
to select the memory channel.
OFF
The buttons adjust the current.
A16
ON
The Plus/Minus remote control is always active.
OFF
The Plus/Minus remote control is active only when
selected by pressing the REMOTE button.
A17
ON
Flow guard on.
OFF
Flow guard off.
A19
ON
Automatic control on.
OFF
Water cooler runs constantly.
A20
ON
Water cooler temperature guard selected.
OFF
Temperature guard off.
A21
ON
Automatic recocnition on, control cannot be selected if it
is not connected.
OFF
Automatic recocnition On/Off. Controller can be selected
even if it is not connected.
A22
ON*
Tail arc on. * 4T LOG
OFF**
Tail arc off. ** MINILOG