6.

TeCHniCal daTa

Power source Mastertig MLS™ 2300 ACDC
Connection voltage
Rated power
40% ED TIG
60% ED TIG
100% ED TIG
40% ED MMA
60% ED MMA
100% ED MMA
Connection cable
Fuse (delayed)
Welding current range
Max welding voltage
Electrode sizes to be welded
Open circuit voltage, max.
Welding current adjustment
Efficiency at nominal values
Power factor
at nominal values
Open circuit power
External dimensions
Weight
Cooling unit (TIG-welding) Mastercool 20
Connection voltage
Connection capacity
Cooling power
Start pressure, max
Cooling liquid
Reservoir volume
External dimensions
Weight
1~230 V –15%...+15%
230 A
5,7 kVA
200 A
4,8 kVA
170 A
3,9 kVA
180 A
6,0 kVA
150 A
4,8 kVA
120 A
3,7 kVA
H07RN-F
3G2.5 (3.3 m)
15 A
TIG
3 A / 10,0 V...230 A / 19,2 V
MMA
10 A / 20,5 V...180 A / 27,2 V
32 V / 180 A (MMA)
Ø 1,5...4,0 mm
58 V
stepless
82 % (180 A / 27,2 V),
78 % (230 A / 19,2 V)
0,99
TIG
6 W
MMA
180 W
LxWxH
430 x 180 x 390 mm
height
650 mm (power source + cooling unit)
15 kg
230 V -15 %...+15 %
100 % ED
50 W
1,0 kW
4,0 bar
20 % - 40 %
glycol-water
approx. 3 l
LxWxH
500 x 180 x 260 mm
8 kg
EN
21