Setup functions

Name on
Parameter
display
value range
A
0 or 1
B
0 or 1
C
0 or 1
d
0,1,2 or 3
E
5 ... 40%
F
0 or 1
h
0.0 ... 2.0s
J
0.0 ... 10.0s
L
5.0 ... 20.0s
o
15 ... 99s
S
-3 ... 5
t
-9 ... 0
( Available from program version 0A7 )
Factory
setting
0
End current level selection. 1=5A, 0=15%
0
Open-circuit voltage selection. 1=30V (VRD), 0=95V
0
Forced stop during downslope with a brief pressing of the switch. 1=On, 0=Off
1
Alternative switch logic. 0=4T LOG,
20%
Start current level as % of the welding current.
0
Restore factory settings. 1=Restore, 0=No restore
0s
Minimum setting of pre-gas time.
1.0s
Minimum setting of post-gas time.
10.0s
Maximum setting of pre-gas time.
30s
Maximum setting of post-gas time.
0
Arc dynamics (Arc Force)
0
Electrode ignition pulse. -9=No pulse, 0=Max pulse
Description
1=Minilog,( 2=4T-LOG+Minilog, 3= Minilog+ search arc )
15

Hide quick links: