welding panel aCX
– pulsed Tig and MinilOg function with memory
1.
EN
1.
4T-LOG and MINILOG function selections
2.
Search arc 5 – 90 % of welding current
3.
Start-current 80 – 150 %
4.
Minilog-current 10 – 150 % of welding current
5.
Tail arc 5 – 90 % of welding current
6.
Selection for spot, synergetic quick pulse and long pulse
7.
Spot time 0,0 – 10,0 s
8.
Pulse current 10 A – power source max.
9.
Pulse ratio 10 – 70 % of pulse time
10. Frequency 0.2 – 250 Hz DC-TIG, 0.2 – 20 Hz AC-TIG
11. Base current 10 – 70 % of pulse current
12. MEMORY, memory function
13. Selection of channel in memory function
14. SAVE/memory values
If wanted in SETUP-function you can disable search arc and tail arc functions. Hot Start (Soft
Start)- and Minilog -currents can be disabled by adjusting the values to 100 per cent (the same
as the welding current).
14
2.
3.
4.
6.
12.
13.
7.
8.
9.
11.
5.
10.
14.