Setup Functions (10) - Kemppi FastMig MSF 53 Operating Manual

Hide thumbs Also See for FastMig MSF 53:
Table of Contents

Advertisement

3.3

SETUP FUNCTIONS (10)

The unit is equipped with a number of functions that can be selected. Parameters can be set
via the SETUP function. The SETUP function is activated by pressing the SETUP button (10)
for >1 second. The adjustable parameter is selected via the left-hand potentiometer (14), the
name of which is shown on display No. 2. The value of the parameter in question is adjusted
via the right-hand potentiometer (16), the value of which is shown on the display (8). The
parameters and their possible values are:
Normal MIG -welding SETUP -parametres
Name of parameter
Pre Gas Time
Post Gas Time
Creep Start Level
Start Power
Post Current Time
Set Voltage Limit
EN
Synergic MIG -welding SETUP -parametres
Name of parameter
Pre Gas Time
Post Gas Time
Creep Start Level
Hot Start Level
Hot Start 2T Time
Crater Fill Start Level
Crater Fill Time
Crater Fill End Level
Start Power
Post Current Time
Synergic MIG Unit
20
Name on
Parameter values
display
PrG
0.0...9.9 s
PoG
0.1 ... 32.0 s
CrE
10...170%
StA
-9 ... +9
PoC
-9 ... +9
U2L
25.0 ... 48.0 V
Name on
Parameter
Factory setting Description
display
values
PrG
0.0...9.9 s
(Syn)
PoG
0.0...9.9 s
(Syn)
Cre
10 ... 170 %
(50 %)
Hot
-50 ... 75 %
(30 %)
H2t
0.0 ... 9.9 s
(1.2 s)
CrS
10 ... 250 %
(30 %)
CrT
0.0 ... 9.9 s
(2.0 s)
CrL
10 ... 250 %
(30 %)
StA
-9 ... +9
(0)
PoC
-9 ... +9
(0)
Unl
mm, m/
(m/min)
min, A
Factory setting Description
0,0 s
Pre gas time in seconds
Aut
Post gas time in seconds or
automatically according to welding
current (Aut)
50 %
Percentage of wire feed speed:
10 % slowed start
100 % = no creep start function
170 % accelerated start
(0)
Strength of start pulse
0
Post current
37.0 (300)
Maximum value for MIG voltage setting
39.0 (400)
42.0 (500)
Pre gas time in seconds or automatically
according to synergic welding program (Syn)
Post gas time in seconds or automatically
according to synergic welding program (Syn)
Percentage of wire feed speed:
10 % slowed start
100 % = no creep start function
170 % accelerated start
Percentage of welding power:
-50 % cold and +75 % hot
The duration of the hot start in seconds in 2T
mode
The welding power at the beginning of the
crater fill stage as a percentage of the welding
power preset value
The duration of the crater fill stage in seconds
(only in 2T mode)
The welding power at the end of the crater fill
stage as a percentage of the welding power
preset value
Strength of start pulse
Post current
In 1-MIG and WiseRoot welding, the parameter
shown in left-hand display: sheet thickness
(mm), wire feed speed (m/min) or average
current (A)

Advertisement

Table of Contents
loading

This manual is also suitable for:

Fastmig msf 57Fastmig msf 55

Table of Contents