Sony HDW-790 Operation Manual page 74

Hide thumbs Also See for HDW-790:
Table of Contents

Advertisement

without losing the synchronization. However, there
will be noise on the recorded image if you connect or
disconnect the time code signal during recording.
Notes
• When you finish the above procedure, the internal time
code is immediately synchronized with the external time
code and the counter display will show the value of the
external time code. However, wait for a few seconds
until the sync generator stabilizes before recording.
• If the frequency of the reference video signal is not the
same as the frame frequency of the camcorder, the
camcorder neither can be correctly genlocked nor can
operate correctly. In such a case, the internal time code
is not correctly synchronized with the external time
code.
• When the GENLOCK ON/OFF item is set to OFF on the
GENLOCK page of the MAINTENANCE menu (page
164), the time code cannot be synchronized with the
reference video signal. In this case, set the GENLOCK
item to ON on the GENLOCK page of the
MAINTENANCE menu.
User bit settings during time code
synchronization
When the time code is synchronized, only the time data is
synchronized with the external time code value. Therefore,
the user bits can have their own settings for each
camcorder.
To synchronize the user bits with external user bit data, set
the EXT-LK UBIT item on the TIMECODE page (page
161) of the MAINTENANCE menu to EXT.
To release the time code synchronization
First disconnect the external time code, then set the F-
RUN/SET/R-RUN switch to R-RUN.
To change the power supply from the battery
pack to an external power supply during time
code synchronization
To maintain a continuous power supply, connect the
external power supply to the DC IN connector before
removing the battery pack. You may lose time code
synchronization if you remove the battery pack first.
Camera synchronization during time code
synchronization
During time code synchronization, the camera is
genlocked to the reference video signal input from the
GENLOCK IN connector.
74
Setting the Time Data

Advertisement

Table of Contents
loading

This manual is also suitable for:

Hdw-790p

Table of Contents