Sony HDW-790 Operation Manual page 163

Hide thumbs Also See for HDW-790:
Table of Contents

Advertisement

No.
Page
Item
M12
PRESET WHT
COLOR TEMP <P> Display color
C. TEMP BAL <P> (–99 to 99)
R GAIN
B GAIN
5600K
AWB ENABLE <P> OFF/ON
M13
DCC ADJUST
DCC FUNCTION
SEL
DCC D RANGE
DCC POINT
DCC GAIN
DCC DELAY TIME
PREKNEE POINT
M14
AUTO IRIS 2
IRIS WINDOW
IRIS WINDOW IND
IRIS LEVEL
IRIS APL RATIO
IRIS VAR WIDTH
IRIS VAR HEIGHT
IRIS VAR H POS.
IRIS VAR V POS.
IRIS SPEED
CLIP HIGH LIGHT
Settings
Default
3200
temperature.
0
<P> (–99 to 99)
0
<P> (–99 to 99)
0
<P> OFF/ON
OFF
OFF
DCC/FIX
DCC
400/450/500/550/
600%
600%
(–99 to 99)
0
(–99 to 99)
0
(–99 to 99)
0
AUTO/FIX
AUTO
1/2/3/4/5/6/VAR
1
OFF/ON
OFF
(–99 to 99)
0
(–99 to 99)
0
20 to 479
240
20 to 269
135
–460 to 460
0
–249 to 249
0
0/1/2/3/4/5
3
OFF/ON
OFF
Description
White balance preset value
The color temperature adjustment is not
satisfactory with COLOR TEMP <P>, adjust
the value more precisely.
R gain preset value
B gain preset value
Turns the electric 5600K filter on/off.
Turns the function for judging the AWB
adjustment when the WHITE BAL switch is
set to PRESET on and off.
Selects the function to be assigned to the
DCC switch.
FIX is fixed knee.
Sets the dynamic range when the DCC switch
is set to the ON position.
For the DCC minimum knee point adjustment
For the gain adjustment to the DCC detected
value
Adjusts the DCC reaction speed.
AUTO: Special dark knee point adjustment is
done with DCC OFF.
FIX: The same preknee point adjustment is
done with DCC OFF as with DCC ON.
Selects the auto iris detection window. VAR is
variable.
Turns the function which displays a frame
marker for the auto iris detection window on
and off.
Adjusts the level of the auto iris target value.
Adjusts the mix ratio of the auto iris detection
peak value and average value.
Sets the width and height of the detection
frame when the auto iris detection window is
set to VAR.
Sets the height of the detection frame when
the auto iris detection window is set to VAR.
Sets the horizontal position of the detection
frame when the auto iris detection window is
set to VAR.
Sets the vertical position of the detection
frame when the auto iris detection window is
set to VAR.
Adjusts the auto iris operation speed.
Turns the function which, during auto iris
adjustment, ignores very bright areas by
dulling the reaction to high luminescence on
and off.
163
Menu List

Advertisement

Table of Contents
loading

This manual is also suitable for:

Hdw-790p

Table of Contents