Installation (for qualified installers only)

Leveling Bolts

This heater includes
front and rear leveling
bolts to accommodate
fireplaces with a step-
down firebox.
NOTE: To access the
rear leveling bolts,
remove the cover plates
and gaskets (replace
after adjustment).

Electrical Requirements

Route the power cord out of the access hole on the right side of the appliance.
Plug the power cord into a grounded 120 Volt outlet (do not remove the grounding pin).
The electrical connection may also be made using the optional Wiring Kit (SKU 97200315).
The appliance, when installed, must be electrically grounded in accordance with local codes or, in
the absence of local codes, with the National Electrical Code, ANSI/NFPA 70, or the Canadian
Electrical Code, CSA C22.1.