Gas Test Button; Wire Inch Button; Channel; 2T/4T Button - Kemppi MXF 63 Operating Manual

Fastmig
Hide thumbs Also See for MXF 63:
Table of Contents

Advertisement

5.3

gas test button

3.
Gas Test function.
Pressing the button will show the gas test time. Gas test time can be adjusted by using the
pulse encoder.
Gas test will proceed after time adjustment is complete (short delay).
Gas test can be stopped by pressing any button.
5.4

Wire inch Button

4.
Wire Feeder will start immediately when the button is pressed.
The default wire inch speed is 5.0m/min.
Wire Inch speed can be adjusted (+/-) using the pulse encoder.
When the button is released the wire feeder will stop. If the button is pressed again, the wire
feeder starts again and slopes to selected wire feed speed (if higher speed is adjusted).
5.5

Channel -

5.
Memory channel down selection.
Panel jumps directly to the previous memory channel that can be found from memory.
5.6
Channel +
6.
Short Press: Memory channel up selection.
Panel jumps directly to next memory channel that can be found from memory.
Long Press: Selected memory channel is locked / unlocked. No panel parameter changes
allowed to that memory channel (panel lock).
5.7

2t/4t Button

7.
Gun trigger logic selection.
Short Press: 2T / 4T selection.
Long Press: MatchLog ON/OFF selection if licence found.