Hatteland HD 12T21 User Manual page 77

Series x maritime multi computer (mmc)
Hide thumbs Also See for HD 12T21:
Table of Contents

Advertisement

Pinout Assignments
Serial COM RS-232 non-isolated, 9-pin DSUB Female
1
2
5
4 3 2 1
9 8 7 6
PIN 01 BUZ+
Buzzer Control Positive*
PIN 02 TxD
Transmit Data
PIN 03 RxD
Receive Data
PIN 04 DTR
Data Terminal Ready
PIN 05 GND
Ground
PIN 06 DSR
Data Set Ready
PIN 07 RTS
Request To Send
PIN 08 CTS
Clear To Send
PIN 09 BUZ-
Buzzer Control Negative*
*Wake On Ring is not enabled
Serial COM RS-232 non-isolated, 9-pin DSUB Male
3
1 2 3 4 5
6 7
PIN 01 DCD
Data Carrier Detect
PIN 02 RxD
Receive Data
PIN 03 TxD
Transmit Data
PIN 04 DTR
Data Terminal Ready
PIN 05 GND
Signal Ground
PIN 06 DSR
Data Set Ready
PIN 07 RTS
Request To Send
PIN 08 CTS
Clear To Send
PIN 09 RI
Ring Indicator
Analog RGB/VGA, 15-pin DSUB High Density Female
1
5 4 3 2 1
10 9 8 7 6
15 14 13 12 11
PIN 01 RED
Red, analog
PIN 02 GREEN
Green, analog
PIN 03 BLUE
Blue, analog
PIN 04 ID2/RES
Reserved for monitor ID bit 2 (grounded)
PIN 05 GND
Digital ground
PIN 06 RED_RTN
Analog ground red
PIN 07 GREEN_RTN Analog ground green
PIN 08 BLUE_RTN
Analog ground blue
PIN 09 KEY/PWR
+5V power supply for DDC (optional)
PIN 10 GND
Digital ground
PIN 11 ID0/RES
Reserved for monitor ID bit 0 (grounded)
PIN 12 ID1/SDA
DDC serial data
PIN 13 HSYNC.
Horizontal sync or composite sync, input
PIN 14 VSYNC.
Vertical sync, input
PIN 15 ID3/SCL
DDC serial clock
Appendix
IND100241-13
B
B
8 9
2
3
A
B
Serial COM RS-485/RS-422, 9-pin DSUB Male
PIN 01 TxD-
PIN 02 TxD+
PIN 03 RxD+ Receive Data Positive
PIN 04 RxD-
PIN 05 GND
PIN 06 N/C
PIN 07 N/C
PIN 08 N/C
PIN 09 N/C
*Master only. ECHO not supported.
Serial COM RS-485/RS-422, 9-pin DSUB Male
PIN 01 Res.
PIN 02 Res.
PIN 03 Data+ Data Positive
PIN 04 Data-
PIN 05 GND
PIN 06 N/C
PIN 07 N/C
PIN 08 N/C
PIN 09 N/C
Half Duplex Configuration: Via Hatteland Display API.
Flow control: Via RTS signal (controlled by user application).
COM Module RS-232 - 4 x ports, 9-pin DSUB Male
Type Number "PCA100294-1"
B
A
PIN 01 DCD Data Carrier Detect
PIN 02 RxD Receive Data
PIN 03 TxD
PIN 04 DTR Data Terminal Ready
PIN 05 GND Signal Ground
PIN 06 DSR Data Set Ready
PIN 07 RTS Request To Send
PIN 08 CTS Clear To Send
PIN 09 RI
77
"Full Duplex Mode*
3
B
1 2 3 4 5
6 7
8 9
Transmit Data Negative
Transmit Data Positive
Receive Data Negative
Signal Ground
No internal connection
No internal connection
No internal connection
No internal connection
"Half Duplex Mode*
3
B
1 2 3 4 5
6 7
8 9
Reserved, do not connect
Reserved, do not connect
Data Negative
Signal Ground
No internal connection
No internal connection
No internal connection
No internal connection
*ECHO not supported.
3
B
1 2 3 4 5
D
C
6 7
Transmit Data
Ring Indicator
8 9

Advertisement

Table of Contents
loading

Table of Contents