Laminated Panels; (Using Securing Brackets - Mounting Off Rear Face) - Mira DISCOVERY Installation And User Manual

Thermostatic mixer
Table of Contents

Advertisement

3. Laminated Panels

(Using Securing Brackets - Mounting off Rear Face)

Note! For laminated panels the shower
control must be positioned from the rear
of the panel.
Panel thickness must be between
4 and 12 mm (if a thicker panel is used, it
will be necessary to recess the securing
brackets into the rear of the panel).
Important! Make sure that there is a
minimum clearance of 64 mm behind
the laminated panel to house the shower
control.
3.1 Remove the two Securing Screws
(retain for later use) and remove the
Shower control from the Building-in
Shroud.
3.2 Mark the position of the Shower
Control using the Building-in Shroud
as a guide.
3.3 Carefully cut out the laminated
panel.
3.4 Fit the Securing Brackets to the
Shower Control.
Important! The brackets must be
fixed vertically, as illustrated.
Important! Make sure that the
correct holes are used, otherwise the
Backplate cannot be fitted.
3.5 Position the Shower Control on
the front of the panel and mark the
position of the M5 fixing holes.
Important! Make sure that the correct
holes are used (refer to illustration).
Note! Make sure that the Filter Plugs
are positioned so that they can be
removed for servicing.
3.6 Drill the two 5 mm holes for the fixing
positions (countersink the holes at
the front).
3.7 Secure the Shower Control with the
M5 x 40 screws as shown.
Backplate
Securing Hole
Backplate
Securing Hole
M5 Fixing Hole
24
M5 Fixing Hole
Filter Plugs
M5 x 40 mm
Fixing Screw

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents