Mira DISCOVERY Installation And User Manual page 38

Thermostatic mixer
Table of Contents

Advertisement

Filters - Built-in Models
To clean or replace the inlet filters:
Note! Refer to the section 'Installation,
Control Assembly' for illustrations.
1.
Isolate the hot and cold water
supplies.
2.
O p e r a t e t h e F l o w L e v e r a n d
Temperature Knob to drain any
residual water.
3.
Rotate the Temperature Control Knob
fully clockwise and carefully pull it
off.
Note! If the knob does not come
off, rotate it fully anticlockwise, pull
on the Temperature Knob while
slowly rotating it clockwise until it
disengages.
4.
Remove the Grey Control Bearing.
5.
Pull off the Flow Lever.
6.
Remove the Flow Lever Adapter.
7.
Carefully remove the Concealing Plate Assembly.
Important! The Lever Retainer must not be removed.
Note! Use a screwdriver in the cutout to assist in the separation.
8.
Unscrew the two Securing Screws and carefully remove the Backplate from
the Shower Control.
9.
Unscrew the Filter Caps with the 'O' Key (supplied) or a 12 mm hexagonal
key.
10. Using pliers, carefully pull out the Inlet Filters.
11. Clean each Filter in turn under a jet of water to remove any lodged particles.
12. Refit the Filters.
13. Refit and tighten the Filter Caps.
14. Restore the hot and cold water supplies and check for leaks.
15. Fit the Backplate to the Shower Control and secure with the two Securing Screws.
Make sure that the Foam Seal is fully compressed. Do not overtighten.
16. With the cutout at the bottom, slide the Concealing Plate over the Shower Control,
engage the crosses in the Concealing Plate with the square recesses in the
Backplate, and push firmly until the Concealing Plate clicks into position.
17. Refer to the section 'Installation, Control Assembly' and follow steps
8 to 12.
'O' Key
38
Filter
'O' Seal
Filter Cap

Hide quick links:

Advertisement

Table of Contents
loading