1.7 Fit the Securing Brackets to the
Shower Control.
Important! Make sure that the
correct holes are used, otherwise the
Backplate cannot be fitted.
Note! The Securing Brackets can be
rotated for suitable fixing points.
1.8 Mark the positions for the Countersunk
Fixing Holes on the wall.
1.9 For solid walls drill two 6 mm holes
for the Wall Plugs.
Caution! Do not drill into pipes in the
wall.
1.10 Fit the Wall Plugs (supplied) and fix
the Shower Control to the wall with
the Securing Screws provided.
Note! For stud partition installations
alternative fixings may be required
(not supplied).
1.11 Connect the hot and cold supply
pipes and tighten the Compression
Nuts.
Caution! Make sure that the Olives
are fitted and all pipework is flushed
through before connecting to the
Shower Control.
1.12 Fit the outlet pipework, leaving
enough pipe through the wall to
temporarily cap off.
1.13 Turn on the water supplies and check
for leaks.