7.1.4 Control Panel Advanced Tab

The Advanced Tab on the Control Panel, shown in Figure 24, provides the ability to control
several advanced camera features as well as the optional spot meter and isotherm modes.
Figure 24: Micron/A10 Control Panel, Advanced Tab
Spot Meter Modes: The A10 camera version provides an optional spot-meter feature. The
spot meter provides a measure of the average blackbody-equivalent temperature imaged by
the four centermost pixels in the image. If your camera includes spot-meter capability, the
Control Panel provides the ability to enable or disable this feature, the ability to read the spot
temperature, and the ability to select Fahrenheit or Celsius temperature scale.
Note: If your camera does not include the optional spot meter feature, you will not have the
option of selecting the Spot Meter modes or reading the spot temperature. However, you will
have the ability to change the temperature units (Fahrenheit or Celsius), which are used for
display of all temperature-related parameters on the Control Panel, including camera
temperature and Isotherm limits.