Long-wavelength (7.5 – 13.5 microns) uncooled microbolometer camera
Table of Contents

Advertisement

ThermoVision® Micron/A10 User's Guide 412-0006-10 Version 130
On-Screen-Symbol Modes: Micron/A10 uses on-screen symbols for displaying important
camera status. Specifically, the following indicators are provided:
a. Overtemp: displayed when the camera is operating above 55
temperature.
b. Low Voltage: displayed when the camera input voltage is below 3.5V (or 7.5V with the
extended voltage-range option).
c. FFC Imminent: displayed nominally 2 seconds before automatic FFC.
d. Low-Sensitivity State: displayed when the camera is in the high-temperature (low-
sensitivity) state. (The "L" icon implies lower sensitivity.)
Figure 22 shows the approximate size and location of each of these indicators on the display.
Three On-Screen-Symbol modes are provided for specifying the color of on-screen symbols:
1. Black / White. In this mode, all icons are display white in white-hot polarity and black in
black-hot polarity.
2. Overbright. In this mode, all icons are displayed 10% brighter than the brightest white
used in the video field.
3. Off. In this mode, display of icons is disabled.
FFC-imminent
indicator
Low-voltage
indicator
Low-sensitivity-state
indicator
Figure 22: Approximate size and location of each on-screen indicator
Outside-Temperature-Range indicator
TEMP RANGE
26
o
C, the maximum specified