Replacing Hdd/Ssd Sas/Sata Backplanes; Replacing The 2.5-Inch Hdd/Ssd Sas/Sata Backplane; Required Tools; Preliminary Steps - Fujitsu PRIMERGY CX400 S1 Upgrade And Maintenance Manual

Server enclosure
Table of Contents

Advertisement

Hard disk drives / solid state drives
7.4

Replacing HDD/SSD SAS/SATA backplanes

7.4.1
Replacing the 2.5-inch HDD/SSD SAS/SATA
backplane
Field Replaceable Units (FRU)
Average hardware task duration: 70 minutes
Average software task duration: 5 minutes
Note on system information
The 2.5-inch HDD/SSD SAS/SATA backplane contains the Chassis ID EPROM
that contains system information like server name and model, housing type,
serial number and manufacturing data.
7.4.1.1

Required tools

Preliminary and concluding steps:
– Phillips PH2 / (+) No. 2 screw driver
Main steps:
– Phillips PH2 / (+) No. 2 screw driver, minimum length 200 mm
7.4.1.2

Preliminary steps

Perform the following procedures:
"Shutting down the server node" on page 41
Ê
"Removing the server enclosure out of the rack" on page 43
Ê
V
CAUTION!
For ALL service tasks, remove the CX400 S1 server enclosure out of
the rack and put it on a separate desk!