7.3.3
Removing 3.5-inch HDD modules
Customer Replaceable Units (CRU)
Average task duration: 5 minutes
7.3.3.1
Required tools
Preliminary and concluding steps: tool-less
●
Main steps: tool-less
●
7.3.3.2
Preliminary steps
Perform the following procedures:
Ê Ensure that the HDD module to be removed is not combined into a RAID
array. If the drive is part of a RAID array, you first need to delete the array
using ServerView RAID Manager.
V
CAUTION!
All data on all HDDs in the array will be lost! Be sure to back up your
data before deleting a RAID array.
I
For further information, please refer to the "ServerView Suite RAID
Management" user guide, available online at
http://manuals.ts.fujitsu.com
supplied with your PRIMERGY server.
CX400 S1
or from the ServerView Suite DVD 2
Upgrade and Maintenance Manual
Hard disk drives / solid state drives
115