7.2.4
Replacing a 2.5-inch HDD/SSD module
Customer Replaceable Units (CRU)
Average task duration: 5 minutes
V
CAUTION!
Only remove an HDD/SSD module during operation if the drive is not
●
currently being accessed. Observe the indicators for the
corresponding HDD/SSD modules, see "PRIMERGY CX400 S1
Server Enclosure Operating Manual".
Under no circumstances should you remove an HDD / SSD module
●
while the system is in operation if you are not sure that the drive is
operated by a RAID controller and belongs to a disk array that is
operating in RAID level 0, 1, 1E, 10, 5, 50, 6 or 60.
An HDD/SSD module can only be replaced during operation in
conjunction with a corresponding RAID configuration.
All HDD/SSD modules (drives) must be uniquely identified so that
●
they can be reinstalled in their original mounting locations later. If this
is not done, existing data can be lost.
7.2.4.1
Required tools
Preliminary and concluding steps: tool-less
●
Main steps: tool-less
●
7.2.4.2
Preliminary steps
Only applicable for removing intact HDD / SSD modules:
Ê Before removing a non-defective HDD/SSD module, put the drive into
"Offline" mode using your RAID configuration software.
7.2.4.3
Removing a 2.5-inch HDD/SSD module
Ê Remove the HDD / SSD module to be replaced from the server as described
in section
"Removing a 2.5-inch HDD/SSD module" on page
CX400 S1
Upgrade and Maintenance Manual
Hard disk drives / solid state drives
107.
109