Replacing A 2.5-Inch Hdd/Ssd Module; Required Tools; Preliminary Steps; Removing A 2.5-Inch Hdd/Ssd Module - Fujitsu PRIMERGY CX400 S1 Upgrade And Maintenance Manual

Server enclosure
Table of Contents

Advertisement

7.2.4

Replacing a 2.5-inch HDD/SSD module

Customer Replaceable Units (CRU)
Average task duration: 5 minutes
V
CAUTION!
Only remove an HDD/SSD module during operation if the drive is not
currently being accessed. Observe the indicators for the
corresponding HDD/SSD modules, see "PRIMERGY CX400 S1
Server Enclosure Operating Manual".
Under no circumstances should you remove an HDD / SSD module
while the system is in operation if you are not sure that the drive is
operated by a RAID controller and belongs to a disk array that is
operating in RAID level 0, 1, 1E, 10, 5, 50, 6 or 60.
An HDD/SSD module can only be replaced during operation in
conjunction with a corresponding RAID configuration.
All HDD/SSD modules (drives) must be uniquely identified so that
they can be reinstalled in their original mounting locations later. If this
is not done, existing data can be lost.
7.2.4.1

Required tools

Preliminary and concluding steps: tool-less
Main steps: tool-less
7.2.4.2

Preliminary steps

Only applicable for removing intact HDD / SSD modules:
Ê Before removing a non-defective HDD/SSD module, put the drive into
"Offline" mode using your RAID configuration software.
7.2.4.3

Removing a 2.5-inch HDD/SSD module

Ê Remove the HDD / SSD module to be replaced from the server as described
in section
"Removing a 2.5-inch HDD/SSD module" on page
CX400 S1
Upgrade and Maintenance Manual
Hard disk drives / solid state drives
107.
109

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents