Rs485 - Bosch VEZ Series Installation Manual

Autodome easy ii
Hide thumbs Also See for VEZ Series:
Table of Contents

Advertisement

AutoDome Easy II
Daisy Chain Multiple Domes
Figure 8.4 Connections for a Daisy Chain Configuration
AutoDome Easy II
Ref. # Wire
1
2
3
4
5
6
7
8.5.4

RS485

RS485 (2-wire (shielded), half-duplex, differential, multi-drop
(32 nodes), 4000 ft cable limit) RS485 is capable of controlling
a true multi-drop network and is specified for up to 32 drivers
and 32 receivers on a single 2-wire bus. The AutoDome Easy II
uses the 2-wire mode, although RS485 can be connected in a 2-
or 4-wire mode.
NOTICE!
The wire shield must be tied to signal at both ends, if 2-wire
twisted pair is used.
Bosch Security Systems, Inc.
100 Ω
Color
C (-)(Biphase) White/Green
C (+)(Biphase) Yellow
Ground
White/Orange
RS485 (+)
Blue
RS485 (-)
White/Blue
Reserved
Violet
Reserved
Gray
Installation Manual
Preparing the Wiring | en
Head End
Ref. # Connection
8
Dome 3
9
Dome 2
10
Dome 1
11
Head End
Biphase
12
C (-) (Biphase)
13
C (+) (Biphase)
14
Shield
F.01U.164.478 | 2.0 | 2010.02