AutoDome Easy II
Alarm Setup Menu Choices:
Menu
Description
Exit
Saves and exits
the menu.
Inputs
Defines physical
Setup
inputs or events
and commands
that can be used
in a rule. There
are twelve (12)
alarm inputs
available.
Inputs 1
Defines the type
of physical
input.
Outputs Setup Menu
Exit...
1. Alarm Output
2. Shot
3. Shot
4. Shot
5. Aux On
6. Transmit
7. OSD
8. NONE
9. NONE
Right / Left: Select Mode
Bosch Security Systems, Inc.
Sub-menu / Description
N.O.: Normally open dry contact.
N.C.: Normally closed dry
contact.
Outputs Setup...
N.O.
Front Door
2
99
1
Focus / Iris: Select Type
Installation Manual
On-Screen Display Menu Navigation | en
1 Physical Output
2-12 Command
Outputs
Default
Setting
N.O.
F.01U.164.478 | 2.0 | 2010.02