Cable Installation For The Mp-Tp12 Back Box; Finalizing The Installation - AMX Modero NXT-1200V Operation/Reference Manual

12" modero video wall/flush mount touch panel (composite/s-video support)
Hide thumbs Also See for Modero NXT-1200V:
Table of Contents

Advertisement

Twelve
#6-32
securing
screws
Internal panel casing
Four (pan-head) Housing Screws
FIG. 34
Location of the attachment screws on the NXD back box and VESA housing

Cable Installation for the MP-TP12 Back Box

1.
Connect the cable connectors (RJ-45, Ethernet, and any other audio/video wiring) to their respective
locations along the side of the touch panel.
2.
Thread the incoming cables through the strain relief grommet opening on the rear plastic cover (FIG. 34).

Finalizing the installation

1.
Gently place the rear plastic cover over the NXD panel (with LCD and MB-TP12 back box).
2.
Insert the protruding cables, coming out from the opening on the rear plastic cover, into the open strain
relief grommet.
3.
Allow some slack/length on these cables as a service loop. This service loop provides enough cable
length so you can later remove the NXD (with connected cables) from the rear plastic cover.
VERIFY THE LENGTH AND LOCATION OF THE INSERTED CABLES. ONCE THE
STRAIN RELIEF GROMMET IS CLOSED, IT IS DIFFICULT TO RE-OPEN.
4.
Carefully apply pressure to close the strain relief grommet over the desired cable location.
Verify the Strain Relief Grommet is securely closed over the cables and the clip is
facing the correct direction (upwards). The process of securing the strain relief
grommet may require the use of pliers. Also verify the length and location of the
inserted cables. Once the strain relief grommet is closed, it is difficult to re-open.
5.
Firmly push the Strain Relief Grommet into the opening (toward the inside) until the rim is securely flush
against the back of the rear plastic cover (FIG. 34).
NXD/T-1200V 12" Modero® Video Wall/Flush Mount Touch Panel
DO NOT REMOVE
Connector
Opening
Securing
hole locations
(3 on each side)
Rear plastic cover
Installation Procedures: NXD-1200V Panels
MB-TP12 back box
Strain relief grommet (Clip facing up)
Rim of the strain relief grommet
should lie flush against enclosure
Four (#8-32) screws