Install the four (#4)
mounting screws
into the holes
(screws not included)
A - Faceplate
FIG. 42
Wall Mount panel installation configuration for flat/solid surfaces
4.
Thread the incoming RJ-45, Ethernet, USB, and any other audio/video wiring (from their terminal
locations) through the cutout opening. Refer to the Wiring Guidelines for the 1200V Panels section on
page 41 for pinout descriptions.
Leave enough slack in the wiring to accommodate any re-positioning of the panel.
5.
Connect all data and power wiring to their corresponding locations along the side of the
(un-powered) NXD touch panel.


6.
Test the incoming wiring by connecting the panel connections to their terminal locations and applying
power. Verify the panel is receiving power and functioning properly before finalizing the installation.
7.
Disconnect the terminal end of the power cable from the power supply.
Don't disconnect the connectors from the touch panel. The unit must be installed with
the necessary connectors before being inserted into the solid surface.
8.
Carefully slide the main unit into the cutout until the Mounting Tabs of the NXD unit lie flush against the
wall.
9.
Insert and secure the four #4 screws into their corresponding holes located along the sides of the NXD
(using a grounded Phillips-head screwdriver) until the unit is secure and flush against the wall.
10.
Place the magnetic faceplate (A in FIG. 42) back onto the main NXD unit (B in FIG. 42).
Make sure to align the Microphone, Light, and PIR Motion sensor locations to their respective openings
on the front bezel/faceplate.
11.
Reconnect the terminal RJ-45, Ethernet, USB, and any optional audio/video wiring to their respective
locations on either the NXA-AVB/ETHERNET Breakout Box, Ethernet port, or NetLinx Master.
NXD/T-1200V 12" Modero® Video Wall/Flush Mount Touch Panel
Attachment is done
along the edges of
the cutout
(bezel)
Verify the terminal end of the power cable is not connected to power supply before plugging in the
2-pin power connector.
The USB connectors can be from a either a USB extension cable, or a wireless USB RF transmitter.
Installation Procedures: NXD-1200V Panels
B - Main NXD unit consists of
the touch panel and housing
Flat surface
(can include a
wall, podium, or
other flat
surface)