Installation Procedures: NXD-1200V Panels
12.
Reconnect the terminal power connector on the 12 VDC-compliant power supply and apply power.

Installing an NXD into an (optional) Rack Mount Kit (NXA-RK12)

1.
Remove the magnetic faceplate/bezel from the main NXD unit by gripping the faceplate and pulling with
gentle outward force.
2.
Thread the incoming RJ-45, Ethernet, USB, and any optional audio/video wiring through the opening in
the equipment rack (from their terminal locations). Refer to the Wiring Guidelines for the 1200V
Panels section on page 41 for pinout descriptions. Leave enough slack to accommodate any re-
positioning of the panel.
3.
Connect all data and power wiring connectors to their corresponding locations along the side of the (un-
powered) NXD touch panel.


4.
Test the incoming wiring by connecting the panel connections to their terminal locations and applying
power. Verify the panel is receiving power and functioning properly to prevent repetition of the
installation.
5.
Disconnect the terminal end of the power cable from the connected power supply.
Don't disconnect the connectors from the touch panel. The unit must be installed with
the necessary connectors before being inserted into the equipment rack.
6.
Insert the main 12-inch Modero unit into an NXA-RK12 (FIG. 43).
FIG. 43
NXD-1200V 12 inch Wall Mount panel installed into an NXA-RK12 Rack Mount Kit
7.
Secure the panel to the NXA-RK frame by first inserting and then tightening the four #4-40 screws
(provided). Line up the four mounting holes and use a grounded Phillips-head screwdriver to tighten the
screws in a clockwise direction.
8.
Insert the NXA-RK (with connected NXD unit) into the equipment rack, making sure to align the screw
holes along the sides on the NXA-RK with the holes in the equipment rack.
9.
Use a grounded Phillips-head screwdriver to secure the NXA-RK (with connected NXD unit) to the
equipment rack using #10-32 screws (not included).
10.
Place the magnet faceplate back onto the main NXD unit by gripping the faceplate and placing it on the
housing with gentle force. Make sure to align the Microphone, Light, and PIR Motion sensor locations to
their respective openings on the front bezel/faceplate.
40
Verify the terminal end of the power cable is not connected to a power supply before plugging in the
2-pin power connector.
The USB connectors can be from a either a USB extension cable, or a wireless USB RF transmitter.
Rack mount
frame (NXA-RK12)
Faceplate