Troubleshooting; Overview - AMX Modero NXT-1200V Operation/Reference Manual

12" modero video wall/flush mount touch panel (composite/s-video support)
Hide thumbs Also See for Modero NXT-1200V:
Table of Contents

Advertisement

Troubleshooting

Overview

This section describes the solutions to possible hardware/firmware issues that could arise during the common
operation of a Modero touch panel.
Troubleshooting Information
Symptom
Manifest.xma can not be found.
An error occurs when sending a
file to a G4 panel.
When using G4 WebControl to
communicate with a target panel, a
VNC Server dialog appears on my
screen.
While attempting to communicate
directly with the Virtual Master (on
the PC) via a USB connection, I
can't get my communication icon
to turn Green.
Calibration is not working.
Panel doesn't respond to my
touches
NXD/T-1200V 12" Modero® Video Wall/Flush Mount Touch Panel
Solution
• Manifest.xma is the file that contains the listing for all the files. If you
see this error again, before attempting to send the file, uncheck the
Smart Transfer box. It may be necessary do a Full Clean.
• During a WebControl connection to a target panel you are prompted
with a G4 Authentication dialog which asks you to enter the assigned
password for the panel (before gaining access).
• If you are ever prompted with a VNC Server dialog, you must enter
the IP Address of the target panel. This can be found within the
Setup > Protected Setup >System Settings page.
- This IP Address of the panel appears within the IP Settings
section of this page
• Enter the IP Address and click OK. You will then be prompted with
the G4 Authentication popup where you must enter the panel's
WebControl password.
• A Green communication icon indicates that a connection has been
established to the target Master or target Virtual Master.
• Launch NetLinx Studio and configure the Master Connection
communication settings for a Virtual Master.
• Navigate to the System Settings page and toggle the Type field to
USB.
• Make sure the Type-A USB connector is securely connected to the
PC.
• Make sure the panel DOESN'T have the mini-USB connected and
TURN OFF the panel.
• Once the panel has turned ON THEN connect the mini-USB to the
Program Port. The USB icon should appear in your system tray. If it
doesn't, refer to the Configuring and Using USB with a Virtual
Master section on page 49.
• The panel can take a few minutes to detect the connection to the PC.
• After the Modero touch panel has been updated with a new firmware
kit (downloaded to the panel through NetLinx Studio), the calibration
could need to be reset.
• Cycling power to the panel should provide a baseline calibration for
the particular touch panel. Proceed to the Calibration page and reset
the on-screen calibration.
• The protective cover acts to press on the entire LCD and makes
calibration difficult because the user can't calibrate on specific
crosshairs when the sheet is pressing on the whole LCD.
• Verify that the protective laminate coating on the LCD is removed
before beginning any calibration process.
Troubleshooting
161