Master Connection Section - Netlinx Master Ethernet Ip Address - Auto Mode; Using G4 Web Control® To Interact With A G4 Panel - AMX Modero CV7 Operation/Reference Manual

7" modero touch panel
Hide thumbs Also See for Modero CV7:
Table of Contents

Advertisement

Configuring Communication
System Address
reflects the value
set in the Device
Addressing tab
Used to obtain an
existing URL
List from Master
Used to set the
URL List
on Master
FIG. 71
URL List dialog

Master Connection section - NetLinx Master Ethernet IP Address - Auto Mode

In this mode, enter the System Number of the NetLinx Master. This mode instructs the Modero to search
for a Master that uses the same System Number (assigned within the Master Connection section) and
resides on the same Subnet as itself.
1. Toggle the blue Type field until Ethernet is selected (from the Master Connection section of the
System Settings page).
2. Press the Mode field until the choice cycles to the word Auto.
3. Press the System Number field to launch a Keypad and enter the value for the system number of the
NetLinx Master. This value can be obtained from the NetLinx Studio program > OnLine Tree of the
Workspace window.
4. Do not alter the IP Settings section, of the System Settings page, as these fields are not applicable to
this connection mode.
5. Enter a username and password (into their respective fields) if the target Master has been previously
secured.
6. Press the on-screen Reboot button to both save any changes and restart the panel.
7. After the panel powers-up, press the grey Front Setup Access button for 3 seconds to open the Setup
page and confirm there is an active connection.
The NetLinx Master and the Modero panel must both be on the same Subnet.
Using G4 Web Control
The G4 Web Control feature allows you to use a PC to interact with a G4 enabled panel via the web. This
feature works in tandem with the new browser-capable NetLinx Security firmware update (build 300 or
higher). G4 Web Control is only available with the latest Modero panel firmware.
Refer to the G4 Web Control Page section on page 101 for more detailed field information.
Verify your NetLinx Master (ME260/64 or NI-Series) has been installed with the latest
firmware KIT file from www.amx.com. Refer to your NetLinx Master instruction
manual for more detailed information on the use of the new web-based NetLinx
Security.
1. Press the grey Front Setup Access button for 3 seconds to open the Setup page.
74
®
to Interact with a G4 Panel
7" Modero Touch Panels