PDU STRAPPING AND CONNECTIONS

3.3
BATTERY INPUT
WIRE SIZE NO. 4 (MAX)
+
A BATT
NEG
POS
'A' BATTERY
'A' BATTERY
'B' BATTERY
-24/-48
+24/+48
E1 E3
E2
CIRCUIT BOARD
LOCATED INSIDE
POWER DISTRIBUTION
PANEL
FRONT VIEW
JUMPER E2 TO E3 AND E5 TO E6 FOR POSITIVE
RACK GND. JUMPER E1 TO E2 AND E4 TO E5 FOR
NEGATIVE RACK GND. ALSO, MOVE CHASSIS GND
TO AGREE WITH RACK GND POLARITY. SEE FIGURE
3-1, POWER CABLE ASSEMBLY INSTALLATION,
AND APPLICATION DWG 3DH031770000 EJZZA.
Figure 3 - 2 PDU (695-6200-001/002) Strapping and Connections (Sheet 1 of 2)
+
B BATT
NEG
POS
'B' BATTERY
-24/-48
+24/+48
E4 E6
E5
TOP VIEW
POWER DISTRIBUTION PANEL
FRONT VIEW – PANEL REMOVED
R3
E15
E7
E8
CONNECT ALM INDICATOR TO
2C
J2B AND J2C FOR 24V OPERATION.
2B
2D
CONNECT TO J2B AND J2D FOR 48V
OPERATION.
2A
ALARM CONNECTOR
(SHOWN POSITIONED
FOR 48V OPERATION).
STRAP E7 TO E15 FOR
POSITIVE INPUT VOLTAGE.
STRAP E8 TO E15 FOR
NEGATIVE INPUT VOLTAGE.
WHT
BRN
ALARM
BLANK
INDICATOR
LMW-7029-sm
06/27/05
3-3