Alcatel MDR-8000 User Manual page 242

Microwave digital radios
Hide thumbs Also See for MDR-8000:
Table of Contents

Advertisement

MCS-11 Master (J307) Cable Connection
A.2.11.1
If the radio is provisioned
nects to J307, is disabled. At a repeater, you can use J310 in lieu of
J307 for connecting the TSM polling engine to the radio.
MCS-11 connector J307 is used to connect to a TSM (-2500, -3500, or -8000) polling engine
at a master terminal.
Recommended connectorized cable assembly – PN 695-4126-007/009/012 (26 AWG 8 pair
shielded, jacketed cable). See Figure A - 13 for shelf connector location and pinout.
J315
J1
J318
J307
J307
J316
J308
J317
J309
J312
J312
J310
Figure A - 13 MCS-11 Connector J307 Location and Pinout
A-22
Note
Repeater
, port 2 on the controller, that con-
J307
8
1
15
9
FRONT VIEW
J301
J301
XMT DATA +
RTN CLK +
XMT CLK +
RCV DATA +
RCV CLK +
RCV CLK -
RCV DATA -
XMT CLK -
RTN CLK -
XMT DATA -
LMW-7218
01/21/04

Advertisement

Table of Contents
loading

This manual is also suitable for:

Mdr-8000iMdr-8000sMdr-8000u

Table of Contents