Zone Bypass Event Displays

This displays the bypassing of system zones.
16-Character Display
Description
26 BYPS 1 2 1017
Zone 26 bypassed by user 12. Press the
left Select key for the zone name and the
right Select key for the time.
32-Character Display
Description
BYP 5:18P 10 / 17
The east window zone was bypassed.
EAST W INDOW
Press a Select key for the zone number
and user number.
Bypass Event Types - There are 3 event types:
BYP - Bypass
RST - Restore
Note: You may sometimes see the user as SWG or SCH. These are
short for Swinger Bypass and Schedule which are automatic functions
that allow the system to bypass a zone.
22
FRC - Force Arm

Zone Event Displays

This section displays alarms, troubles, and other events that could
occur on your protection zones.
16-Character Display
Description
2 BURG ALR 1017
A burglary alarm occurred on zone 2.
Press the right Select key for the time the
alarm occurred.
32-Character Display
Description
A LR 10: 23P 10/17
An alarm occurred at 10:23
BAS EM ENT DOOR
Press any Select key to see the zone
number and zone type.
Zone Type - There are 7 possible zone types you may see here.
FIRE - Fire
PANC - Panic
EMRG - Emergency
SUPV - Supervisory
AUX1 - Auxiliary 1
AUX2 - Auxiliary 2
Event Types - There are 7 event type you may see here:
ALR - Alarm
TBL - Trouble
LOW - Low battery
MIS - Missing xmitter
FLT - Zone Fault
SVC - Service Smoke Detector
Note: LOW and MIS are for wireless systems only.
on Oct. 17.
PM
BURG - Burglary
RST - Restore