Six Month System Maintenance; Annual Maintenance - Watts Premier HT-5-VOC-B Installation, Operation And Maintenance Manual

Reverse osmosis system
Table of Contents

Advertisement

Annual Maintenance

Items needed:
√ Stage 1 - Sediment Filter (part #: 104017) √ Stage 2 - Carbon Block Filter (part #: 101009)
√ Stage 4 - Carbon VOC (part #: 101013)
Sanitizing of unit is recommended.
Note:
Step 1
Perform steps 1 through 5 in the Six Month System Maintenance (Page 11).
Note:
If not sanitizing the system skip to step 8.
Remove the VOC filter from stage 4 filter housing and discard old filter.
Step 2
Step 3
Remove the RO membrane from its housing and rest in a clean sanitary place. (Refer to
"Membrane Replacement" section on page 13 for directions on removing the membrane).
Replace cap onto empty membrane housing and re-connect tubing.
Leaving the filters out, replace stage 2 and 4 empty filter housing (hand tight) onto unit.
Step 4
Measure & pour either 1/2 cup of hydrogen peroxide or common household bleach into
the 1st filter housing (Stage 1) and hand tighten onto unit. Ball valve on RO tank should
be open.
With the RO faucet in the closed position turn on the incoming water supply to the system
Step 5
by turning the adapt-a-valve counter clockwise. Plug in the power transformer back into the
electrical outlet. Wait 1 minute for the unit to pressurize. Turn on the RO faucet and let the
water run for 30 seconds. Turn off the RO faucet and let the unit rest for 2 minutes. Finally,
open the RO faucet and let the water run for 5 more minutes.
Step 6
Unplug the Power Transformer. Turn off the incoming water supply to the system by turning
the adapt-a-valve clockwise until it stops. Keep the RO faucet open until the storage tank
is completely drained.
Open the membrane housing and re-install the RO membrane while making sure not to kink
Step 7
the O-rings.
installing the membrane).
Remove filter housings Stage 1, 2 and 4 and empty of water.
Step 8
Before re-installing the filter bowls back on to the system , check O-rings to make sure
Caution:
they are still in place and lubricate with water soluble lubricant.
Insert the new sediment filter (cloth like appearance) into the 1
Step 9
on the water inlet side (green tubing from the adapt-a-valve) of the RO system and
re-install housing.
Insert the new Carbon Block filter (White End Caps) into the 2nd housing and VOC block
Step 10
filter into 4th housing and re-install housings onto system.
Remove the final filter from the two clips. Remove the fittings from both ends of the filter
Step 11
(keep and re-teflon if needed). Discard the old filter and replace with new filter reusing the
connectors .
Note: Flow arrow on final filter must be pointing in the direction of water flow to the RO faucet.
This is a good time to check the air pressure in your storage tank. For instructions
Tip:
please see page 14.
Follow Start Up procedure on page 10. You will need to flush a half a gallon of water
Step 12
before using the RO water .
(Refer to "Membrane Replacement" section on page 13 for directions on
Tighten the cap back on the housing and reconnect tubing.
√ Stage 5 - Final In-line Filter (part #: 100004)
Page 12
filter housing which is the one
st

Advertisement