5. Pressing the [0] button while holding down the [MONI-
TOR] button will toggle the background camera
images and black on the active monitor.
6. To exit as it stands, select a new monitor.
7. To exit from the mode, press the [CLEAR (ESC)] but-
ton while holding down the [MONITOR] button or select
a camera to be displayed on the active monitor.
Video Loss Status Table
The table shows the video loss detection status up to 1 024
MXCONT inputs on the active monitor.
1. Select a monitor for displaying the status.
Refer to the Monitor Selection.
2. Pressing the [2] button while holding down the [MONI-
TOR] button will display the VIDEO LOSS STATUS
table as shown in the figure on the active monitor.
VIDEO LOSS STATUS
CAM
PORT#
1
1
2
2
3
3
4
4
5
5
6
6
7
7
8
8
9
9
10
10
GROUP PRESET
PREV
OPE ID
S-CTL ID
LOG OUT
PAUSE
CAM MENU OFF
GROUP
F1
SEQ
F2
OSD
CAM FUNC
The columns in the table indicate the states as shown
below.
CAM: Logical Camera Number
PORT#: Video Input Port Number
STATUS:
ABOVE/IN: Video level is above normal and in
sync.
BELOW/IN: Video level is below normal and in
sync.
ABOVE/OUT: Video level is above normal and out
of sync.
114
PG 1
STATUS
LOCATION
ABOVE/IN
FRAME1
BELOW/OUT
FRAME1
ABOVE/IN
FRAME1
BELOW/OUT
FRAME1
ABOVE/IN
FRAME1
ABOVE/IN
FRAME1
ABOVE/IN
FRAME1
ABOVE/IN
FRAME1
ABOVE/IN
FRAME1
ABOVE/IN
FRAME1
T&D
CAM ID
GEN
NEXT
AUX1 OFF
AUX1 ON
WIPER
ALM S
VLD S
SYS S
STOP
MON STATUS
ALL
CAM MENU ON
AUX2 OFF
AUX2 ON
TOUR
ALM H
VDL H
SEQ
DEF OFF
DEF ON
CLEAR
( ESC )
MONITOR
SHIFT
BLK
EXIT
LOCK
OSD SERVICE
BELOW/OUT: Video level is below normal and out
of sync.
LOCATION: Logical cage number that the port
belongs to.
3. Press the [NEXT] button to select the next page of the
status, and press the [PREV] button to back up to the
previous page.
4. Press the [NEXT] button while holding down the
[SHIFT] button to select the first page of the status,
and press the [PREV] button while holding down the
[SHIFT] button to select the last page.
5. Pressing the [0] button while holding down the [MONI-
TOR] button will toggle the background camera
images and black on the active monitor.
6. To exit as it stands, select a new monitor.
7. To exit from the mode, press the [CLEAR (ESC)] but-
ton while holding down the [MONITOR] button or select
a camera to be displayed on the active monitor.
System Status Table
The table shows the system status in real time.
1. Select a monitor for displaying the status.
Refer to the Monitor Selection.
2. Pressing the [3] button while holding down the [MONI-
TOR] button will display the SYSTEM STATUS table as
shown in the figure on the active monitor.
MON
ARE
CAM
1
0
2
2
0
3
3
0
-
4
0
10001
5
0
1
T1001R
6
0
-
7
0
-
:
:
-
1023
128
-
9999
128
-
GROUP PRESET
PREV
NEXT
OPE ID
S-CTL ID
LOG OUT
PAUSE
STOP
CAM MENU OFF
CAM MENU ON
GROUP
TOUR
F1
SEQ
SEQ
F2
OSD
MONITOR
CAM FUNC
LOCK
OSD SERVICE
SEQ
DEV
USRID
PRTY
T1
P ALM
20
5
-
S4
101
6
-
K2
105
65535
-
-
-
-
K3
106
8
G2
P K128
-
-
G2
P K128
-
-
-
-
-
-
-
-
-
-
-
-
-
-
T&D
CAM ID
GEN
AUX1 OFF
AUX1 ON
WIPER
ALM S
VLD S
SYS S
MON STATUS
ALL
AUX2 OFF
AUX2 ON
ALM H
VDL H
DEF OFF
DEF ON
CLEAR
( ESC )
SHIFT
BLK
EXIT

Advertisement