Approvals & codes
These appliances are certi ed by ANSI Z21.88a-2012/
CSA 2.33a-2012 American National Standard / CSA
Standard for Vented Gas Fireplace Heaters for use in
Canada and USA. These appliances are for installation
directly venting through an outside wall or through the
roof.
Conversion between fuels may only be done using the
approved conversion kits listed in the section Options.
These appliances comply with CSA P4.1-09 Testing
method for measuring annual fi replace effi ciencies.
The installation must conform with local codes or, in
the absence of local codes with the National Fuel Gas
Code, ANSI Z223.1 or the Natural Gas and Propane
Installation Code CAN/CGA-B149. Only quali ed
licensed or trained personnel should install these
appliances.
These appliances, when installed, must be electrically
grounded in accordance with local codes or, in the
absence of local codes, with the National Electrical
Code, ANSI/NFPA 70 or the Canadian Electrical Code,
CSA C22.1.
Ratings
Model
Gas
Altitude (Ft.)
Input Max. (Btu/h)
Input Min. (Btu/h)
Manifold pressure (in w.c..)
Min. Supply pressure (in. w.c.)
Max. Supply pressure (in. w.c.)
*Tested to CGA - 2.17-91 High Altitude Standard in
Canada. In the USA, installations may require deration
over 2000 feet——check local codes.
*High Altitude Installations
Input ratings are shown in BTU per hour and are
certi ed without deration for elevations up to
4,500 feet (1,370 m) above sea level.
For elevations above 4,500 feet (1,370 m) in USA,
installations must be in accordance with the current
ANSI Z223.1 and/or local codes having jurisdiction.
Heating value of gas in some areas is reduced to
compensate for elevation——consult your local gas
utility to con rm.
For installations at elevations above 4,500 feet
(1,370 m) in Canada, please consult provincial
and/or local authorities having jurisdiction.
Speci cations
JLN/IRN JLP/IRP
Natural
Propane
0-4500 *
24,000
24,000
6,500
13,000
3.95
10.0
5.0
11.0
11.0
14.0
Supply Gas
Heater engine units 534JLN/IRN are used with natural
gas installations.
Heater engine units 534JLP/IRP are used with propane
gas installations.
The supply pressure
must be between the
limits shown in the table
above.
The supply connection is
inch NPT.
The opening for the
gas supply line is at the
left side of the
X
appliance.
Wall Thickness
The vent system (when horizontally terminated)
is appro-ved to pass through combustible wall
construction of up to 14 inches (36 cm) thick.
A non-combustible wall can be any thickness up to the
maximum horizontal run of vent pipe allowed for the
particular installation——see Venting section.
Venting options
Co-axial direct vent installations (solid piping)
A list of all approved venting accessories is shown on
pages 43––44 of this manual.
NOTE: An 817VAK Vent Adapter is required in all
cases when using vent components other than Valor’' s
551DVK Standard Vent Terminal.
Co-linear direct vent installations (fl exible piping)
Converts the appliance outlet collars to accept two
3-inch diameter  ex liners for installation into existing
solid-fuel burning  replaces and chimneys. Requires a
co-linear adapter at the appliance and either a co-linear
terminal or co-linear-to-co-axial adapter and terminal
at the top of the chimney. A list of approved venting
accessories is shown on pages 43––44 of this manual.
Floor/Hearth
This appliance is approved for installation directly on
combustible material such as plywood and so on. Vinyl,
carpet, and soft  ooring require sheet metal extending
the whole width and depth under the appliance.
This appliance does not require a hearth. Combustible
 ooring may extend up to the front of the unit.
QUALIFIED
INSTALLER
X
17
17