(Function mode 1)
Display
Function
sequence
No.
9
F-08
Accelera- tion stop
tion halt
10
F-09
11
F-10
Running
mode
12
F-11
Multistage speed
speed
CTi Automation - Phone: 800.894.0412 - Fax: 208.368.0415 - Web: www.ctiautomation.net - Email: info@ctiautomation.net
(Function mode 2)
Function
Initialization display
name
contents
Accelera-
Fsp F
0000.0 Hz
frequency
setting
Accelera-
Fsp TIME
tion stop
time setting
Pattern
PARAM
command-
ing method
selection
Running
RUN MODE
mode
selection
Restarting
RUN FRS
after FRS
signal
selection
Multistage
SPD 1
0000.00 Hz
1 speed
setting
Multistage
SPD 2
0000.00 Hz
speed
2-speed
setting
Multistage
SPD 3
0000.00 Hz
speed
3-speed
setting
Multistage
SPD 4
0000.00 Hz
speed
4-speed
setting
Multistage
SPD 5
0000.00 Hz
speed
5-speed
setting
Multistage
SPD 6
0000.00 Hz
speed
6-speed
setting
Multistage
SPD 7
0000.00 Hz
speed
7-speed
setting
Setting, change
Initialization
0 Hz
00.0 s
0 s
REM
REM
REM/
OP1/OP2
(Option
connected)
NOR
NOR
NOR/OEN/
ZST
ZST
0 Hz
0 to 120.0 (400)
0 Hz
0 to 120.0 (400)
0 Hz
0 to 120.0 (400)
0 Hz
0 to 120.0 (400)
0 Hz
0 to 120.0 (400)
0 Hz
0 to 120.0 (400)
0 Hz
0 to 120.0 (400)
12-7
Setting contents
contents
0 to 400.0
• The frequency at which the
acceleration operation is
stopped temporarily is set.
0 to 60.0
• The time that the acceleration
is stopped temporarily at a
certain frequency during
acceleration is set.
• The parameter setting com-
manding source is selected.
REM (each operator),
OP1 (option 1), OP2 (option
2)
NOR:
Normal running
GOD
OEN:
Energy conservation
running
GOD:
Fuzzy most suitable
acceleration and
deceleration running
fST/ZST
fST:
Restart after frequency
maching
ZST:
0 Hz start
• The input terminal CF1 is set
and used.
• The input terminal CF2 is set
and used.
• The input terminals CF1 and
CF2 are set and used.
• The input terminals CF1 and
CF3 are set and used.
• The input terminals CF2 and
CF3 are set and used.
• The input terminals CF1, CF2,
and CF3 are set and used.
• The input terminal CF3 is set
and used.