Control Circuit Terminals - Hitachi J300 Series Instruction Manual

J300 series
Hide thumbs Also See for J300 Series:
Table of Contents

Advertisement

5.6

Control Circuit Terminals

Terminal symbol
FM
CM1
PLC
P24
FW
REV
CF1
CF2
CF3
(NOTE 1)
JG
DB
STN
SET
CH1
FRS
EXT
USP
CS
SFT
AT
RS
UP
DWN
CTi Automation - Phone: 800.894.0412 - Fax: 208.368.0415 - Web: www.ctiautomation.net - Email: info@ctiautomation.net
Terminal name
Monitor terminal
Common terminal 1
Internal interface common
Input signal power source
Forward run/stop terminal
Reverse run/stop
SW1
Multistage speed
SW2
SW3
Jogging
External DC braking
Initialization
2nd function
Two-stage acceleration
or deceleration
Free run stop
External trip
Power-ON restart
prevention
Commercial power source
switching
Terminal software lock
Analog input command
Reset
Remote control function,
acceleration
Remote control function,
deceleration
Analog: Output frequency, current, torque
Digital: Output frequency x frequency converted value
(Set in the remote operator monitor mode), max. pulse: 3.6 kHz
Common terminal for the monitor terminal
Common terminal for the external power source of the sequencer
Internal power source for the contact input terminal and frequency
monitor terminal, 24 VDC.
Common for the FW terminal and intelligent input terminals
OUTPUT frequency
Forward
Reverse
SWF
ON
SWR
ON
Frequency
(Hz)
Fourth (FS)
speed
Third
speed
Second
speed
First
speed
Switch
SW1
ON
ON
SW2
ON
SWF
ON
Jogging run
DC braking input signal
Initialization (shipment status at factory) input
The output frequency setting, base and maximum frequencies,
control method, motor constant, acceleration or deceleration time,
manual torque boost setting, and electronic thermal setting are
changed in batch.
The acceleration or deceleration time or selection of two-stage
accration or deceleration is changed by turning the contact ON.
The inverter stops and the motor stops free run
FRS functions when the contact is opened. (European version)
External trip input signal (The contact is open.)
Restart prevention when the power is turned on in the RUN
state (The contact is open.)
Switch signal from the commercial power source to inverter
drive (Note: When the terminal is used, a trip is also conceled.)
The data of all funcitons except for output frequency setting is
locked. See 12-9 [F-25].
Analog input voltage-current switching (When the contact is ON,
current input signal to OI-L is acrive.)
Trip or alarm signal is reset.
When the contact is turned ON, the operation is accelerated.
(Available only when the frequency command is sent
to the operator.)
When the contact is turned ON, the operation is decelerated.
(Available the frequency command is sent to the operator.)
5-12
Description
CM1 PLC P24 FW
8
SWF
CM1
PLC P24 FW 8
Time
SWF
• When setting frequency,
ON
ON
connect P24 and 6 or 7
ON
and set with digital
operator
•••••
1
SWR
(Source type)
7
6
SW1 SW2
or
.
1
2